SPECIFICATIONS
WallMaster Thru-the-wall Air Conditioners Brochure_2015 (1-15) 
Printed in USA
ENERGY STAR
®
 models
HEATING PERFORMANCE: Change-over from heat pump operation to resistance 
operation on models indicated is automatic at a preset outside ambient temperature 
of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does 
not exceed the resistance heating capacity rating of the unit, the heating perfor-
mance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an 
optional drain kit is available. 
DEFROST CONTROL:  Initiated at 30°F (outdoor coil temperature) and terminated 
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the 
electric heat starts,  then operates with the fan to maintain indoor comfort. Below 
43°F, the unit remains in electric heat mode. 
DEFROST DRAIN:  Drain automatically opens at approximately 50°F to prevent 
condensate from freezing inside drain pan.
Heat Pump heating information 
(
shown in red)
 indicates heat pump heating performance. Electric Heat heating information 
(shown in red) 
indicates electric heat 
strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
LISTED
ROOM AIR CONDITIONERS
183H
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
As an 
ENERGY STAR
®
 partner, Friedrich Air Conditioning Co. has determined that the selected 
ENERGY STAR
®
 
models meet the 
ENERGY STAR
®
 guidelines for energy efficiency.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity
cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
WallMaster
®
Model Number
Circuit 
Rating
Breaker
 or T-D Fuse
Plug 
Face
(NEMA#)
Power 
Cord 
Length 
(ft.)
Wall
Outlet
Appearance
WS08D10, WS10D10 and 
WS12D10.
125V - 15A
5 - 15P
6
WS10D30, WS12D30 and
WS15D30.
250V - 15A
6 - 15P
6
WE10D33, WE12D33 and WE15D33. 
WY09D33 and WY12D33.
250V - 20A
6 - 20P
6
Model
Carton Dimensions 
INCHES
Height
Width  
Depth
WallMaster
®
WSE Sleeve
18"
27 1/4"
18"
Chassis
19 3/8" 30 5/8" 27 1/2"
Friedrich Air Conditioning Co.  
l  10001 Reunion Place, Suite 500  l  San Antonio, TX 78216  l  877.599.5665  l  www.friedrich.com
PLUG FACE/CIRCUIT RATING 
Model
Cooling Btu Heating Btu
Volts 
Rated
Cooling 
Amps
Cooling 
Watts
Heating 
Watts
Heating 
Amps
EER
CEER
Estimated 
Yearly 
Energy 
Cost
COP
Moisture 
Removal 
Pints per 
Hr.
Model 
CFM
Net Wt 
Lbs
Ship Wt 
Lbs
Cooling only
WS08D10
8000
 NA 
115
6.4
769
 NA 
 NA 
10.4
10.2
$69
— 
1.8
250
93
97
WS10D10
9700
 NA 
115
8.0
990
 NA 
 NA 
9.8
9.7
$89
 —  
2.4
260
103
107
WS10D30 10000/9800
 NA 
230/208 4.5/4.9 1020/1000
 NA 
 NA 
9.8/9.8 9.7/9.7
$92
 —  
1.5
260
101
105
WS12D10
12000
 NA 
115
10.8
1224
 NA 
 NA 
9.8
9.7
$110
 —  
3.5
295
112
116
WS12D30 12000/11700
 NA 
230/208 5.5/5.8 1224/1194
 NA 
 NA 
9.8/9.8 9.7/9.7
$110
 —  
3.5
290
109
113
WS15D30 14500/14200
 NA 
230/208 7.0/7.5 1559/1527
NA
NA
9.3/9.3 9.3/9.3
$140
 —  
4.8
290 
119
123
Heat pumps
WY09D33
9000/9000
8100/7800 
230/208 4.4/4.7
918/918
880/830
4.1/4.4
9.8/9.7 9.7/9.7
$83
2.70/2.75
2.5
260
103
107
WY12D33 11500/11300
9200/8800
230/208 5.5/5.8 1237/1215
1227/1158 5.5/5.8
9.3/9.3 9.3/9.3
$111
2.20/2.23
3.4
275 
111
115
Cooling with electric heat
WE10D33 10000/9800
11000/9100
230/208 4.5/4.9 1020/1000
3550/2950 16.0/14.7
9.8/9.8 9.7/9.7
$92
— 
1.5
260
104
108
WE12D33 12000/11700
11000/9100
230/208 5.5/5.8 1224/1194
3550/2950 16.0/14.7
9.8/9.8 9.7/9.7
$110
 — 
3.5
290
107
111
WE15D33 14500/14200
11000/9100
230/208 7.0/7.5 1559/1527
3550/2950 16.0/14.7
9.3/9.3 9.3/9.3
$140
 —  
4.8
290 
119
123