For complete information, see installation instructions packed with your dryer.
Ducting Materials:
 
For best performance, this dryer should be vented with 4" diameter all rigid metal 
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-
rigid) ducting can be used (Kit WX08X10077). In special installations, it may be 
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. 
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid 
metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter 
can be maintained throughout the entire length of the transition duct. Please see 
installation instruction packed with your dryer for complete instructions when using 
flexible metal (foil type) ducting. 
Exhaust Length Calculation: 
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the 
side or bottom of dryer, add one turn.
2.  The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated 
is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the 
duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 
90° elbow.
Dryers 
must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any 
enclosed house floor (crawl space), or into an attic, since the accumulated lint could 
create a fire hazard or moisture could cause damage. Never terminate the exhaust 
into a common duct or plenum with a kitchen exhaust, since the combination of lint 
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, 
bird nesting, etc. The wall cap must also be located at least 12" above the ground or 
any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
GTD81GSSJ/GSPJ
GE
®
 7.8 cu. ft. capacity gas dryer with aluminum alloy 
drum
Specification Created 1/15
Dryer exhausting information—use metal 
duct only vertical and horizontal ducting
A
B
2-1/2
4
GE Dryer Vent
A
B
2-1/2
4
GE Dryer Vent
A
Best performance
Maximum length  
of 4" dia 
rigid  
metal duct
Exhaust hood type
Domestic dryer models 
Number 
of 90° 
turns
A
4"  
opening
B
2-1/2" 
opening
GE Frontload Long Vent 7.0 
cu. ft. capacity electric dryer 
(GFDL)
0
200 ft.
175 ft.
1
185 ft.
165 ft.
2
175 ft.
155 ft.
3
165 ft.
145 ft.
4
155 ft.
135 ft.
5
145 ft.
125 ft.
Long Vent 6.0 - 8.0 cu. ft.  
capacity electric & gas dryers 
(GTDL and GTV)
0
150 ft.
125 ft.
1
135 ft.
115 ft.
2
125 ft.
105 ft.
3
115 ft.
95 ft.
4
105 ft.
85 ft.
5
95 ft.
75 ft.
Long Vent 7.0 cu. ft. capacity 
electric & gas (GTD42, GTD45, 
GTD65, GTX42 and GTX60)
0
120 ft.
90 ft.
1
100 ft.
75 ft.
2
85 ft.
65 ft.
3
70 ft.
55 ft.
4
60 ft.
45 ft.
5
55 ft.
35 ft.
All 6.0 - 8.3 cu. ft. capacity 
models electric and gas dryers 
(GFDS, GFDR, GFDN, GTDS, 
GTDN, GHDN, GHDS, GTDP, 
GLDP, GTD, HTDP, HTDX)
0
90 ft.
60 ft.
1
60 ft.
45 ft.
2
45 ft.
35 ft.
3
35 ft.
25 ft.
4
25 ft.
15 ft.
DCVH480
0
90 ft.
60 ft.
1
60 ft.
45 ft.
2
45 ft.
35 ft.
3
35 ft.
25 ft.
All 3.6 cu. ft. (DSKS, DSKP)
electric dryers
0
46 ft.
37 ft.
1
37 ft.
30 ft.
2
30 ft.
22 ft.
3
23 ft.
15 ft.
Laundry Center GUD27
0
56 ft.
42 ft.
1
48 ft.
34 ft.
2
40 ft.
26 ft.
3
32 ft.
18 ft.
Laundry Center GUD24
0
43 ft.
36 ft.
1
33 ft.
26 ft.
2
24 ft.
16 ft.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow. 
For the side exhaust installations, add one 90° elbow to the chart. 
The total vent system length includes all the straight portions and elbows of 
the system (transition duct included).