Dacor DR30GFSNGH Guia Da Instalação
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
DR30GI[F]S Range with ERV3015
Raised Vent
Document # PGCI-028
Revised 10/07/13 Page 1/1
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
1 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). Width notches remains 30”.
2 For 24 to 24 1/4 inch deep cabinets, the side panels and control panel will protrude from the cabinet face a total of 5 5/8 inches.
3 Revision A ranges only: Raised vent trim piece and 3 1/2 inch side panels (Dacor PN ADTK30GSR24) must be installed to cover the
front of the raised vent chassis in back and range chassis on sides.
4 Revision A ranges only: Optional raised vent trim piece (Dacor PN ADTK30GSR) must be installed to cover the front of the raised
vent chassis in back.
For all installations with a raised vent:
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
NOTE: For all raised vent installations, use only Dacor raised vent model
ERV3015. This configuration is not compatible with cabinet blower model
CABP3.
CUSTOM CABINET 27 1/2” OR DEEPER,
PARTIAL SIDE PANELS REMOVED (TOP VIEw)4
SIDE VIEw - DR30GI[F]S RANGE AND
ERV3015 RAISED VENT
24 1/4” - 27 1/2” CABINET DEPTh
PARTIAL SIDE PANELS INSTALLED (TOP VIEw)4
24” - 24 1/4” CABINET DEPTh
PARTIAL SIDE PANELS INSTALLED (TOP VIEw)2, 3
RAISED VENT (SELF-RIMMING) INSTALLATION CUTOUT OPTIONS (MODELS DR30GIS AND DR30GIFS ONLy)
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3”
(7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
20 5/8”
(52.4 cm)
raised vent opening
27 1/2” (69.9 cm)
Cabinet face
Countertop
IMPORTANT: If optional side panels are not installed cabinet
face must be flush with back of control panel.
Back of
control panel
DR30GI[F]S
range
3/8” min. (1.0 cm)
space behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm) flat countertop
overhang required behind cutout
Shown with partial
side panel installed
29 1/2” (74.9 cm)
ERV3015
raised vent
Stiffener
Wall
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3”
(7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
Countertop overhang
1 5/8” (4.1 cm) max.
24 1/8”
(61.3 cm)
raised vent opening
27 1/2” (69.9 cm)
20 7/8”
(53.0 cm)
to
24 1/8”
(61.3 cm)
Countertop
front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/8” (9.5 mm) min.
countertop overhang
3” (7.6 cm)
10” min. (25.4 cm)
to any combustibles
above counter both sides
20 5/8”
(52.4 cm)
raised vent opening
27 1/2” (69.9 cm)
25 3/4”
(65.4 cm)
max.
1
1
1