Fujitsu MAP3735FC Manual Do Utilizador

Página de 114
5.2 Setting
C141-E163
5-3
5.2
Setting
5.2.1
Loop ID setting
When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1.  IN bit
weighting, SEL6 corresponds to the MSB, SEL0 to the LSB, and 126 types of X'00' to X'7D' can be
specified as loop IDs.
5.2.2 
Mode settings
(1) 
Motor start mode
The method for start control of the IDD spindle motor can be set in accordance with Table 5.1.
Table 5.1
Motor start mode
Setting
Signal name
Start_2/Mated
Start_1/Mated
Start mode
Connector pin
CN1-10
CN1-09
Open
Open
The drive is not connected to the system.  The drive does not start the
spindle motor.
Open
GND
The drive is connected to the system.  After recognizing the
connection, the drive starts the spindle motor upon receipt of a
START/STOP UNIT command.
GND
Open
The drive is connected to the system.  After recognizing the
connection, the drive starts the spindle motor after a prescribed delay
time has elapsed.
GND
GND
The drive is connected to the system.  The driver starts the spindle
motor immediately after recognizing the connection.
Set  the  loop  ID  so  that  there  are  no  duplicates  between  devices  on  the  same
loop.