Normal and Fault Condition LED Messages
100
AX1500 Motor Controller User’s Manual
 Version 1.9b. June 1, 2007
Output Off / Fault Condition
The controller LED will tun On solid to signal that the output stage is off as a result of a any 
of the recoverable conditions listed below. 
Over temperature
Over Voltage
Under Voltage
The controller will resume the normal flashing pattern when the fault condition disappears. 
A rapid continuously flashing pattern indicates that the controller’s output is Off and will 
remain off until reset or power is cycled. Activating the emergency stop will cause the con-
troller to stop in this manner. A permanent error will also be triggered if the encoder mod-
ule is mounted and an encoder error is detected. Note that while the controller is Off, it will 
continue to respond to commands if in the RS232 mode, and can thus be reset by sending 
the %rrrrrr command.
RC Mode
RS232 Mode No Watchdog
RS232 Mode with Watchdog
Analog Mode
FIGURE 59. Status LED Flashing pattern during normal operation
Temporary Fault
Permanent Error
FIGURE 60. Status LED Flashing pattern during faults or other exceptions