RoboteQ AX2550 Manual Do Utilizador

Página de 186
AX1500 Motor Controller User’s Manual
167
Loading, Changing Controller Parameters
accelerate a motor from idle to maximum speed. See “Programmable Acceleration” on 
page 45
.
Analog or R/C Specific Settings
The screen shown in Figure 92 slightly changes in function of whether or not the Analog 
Input mode is selected. 
If the Analog Input mode is selected on the main screen, then this page is used to set the 
Analog Deadband value. In the R/C mode, this page is used to view and change parame-
ters used in the R/C mode of operation. None of these parameters has any effect when 
running the controller in RS232 mode. 
If the controller is configured in RS232 mode, some of these menus will turn gray but will 
remain active.
1- Deadband
This slider will let you set the amount of joystick motion off its center position before the 
motors start moving. The slider will work identically in the R/C or analog mode, however, 
the % value will be different. See “Joystick Deadband Programming” on page 108 and 
“Analog Deadband Adjustment” on page 117.
2- Joystick Timing
These fields are enabled only if the R/C mode is selected. These number areas will let you 
read and modify the R/C pulse timing information used by the controller. New values can 
be entered manually to create different capture characteristics. They are also useful for 
viewing the stored values after an automatic joystick calibration sequence. See “Joystick 
Calibration” on page 110 and “Activating the Accessory Outputs” on page 110.
FIGURE 92. Power settings screen
1
2