Connecting to the 15-pin Connector
The controller’s I/O are located on it’s standard 15-pin D-Sub Connector. The functions of 
some pins varies depending on controller model and operating mode. Pin assignment is 
found in the table below.
Pin
Signal
RC Mode
RS232 Mode
Analog Mode
1
2A Digital Output C (same as pin 9)
2
TxData
3
RC Ch1
RxData
Unused
4
RC Ch 2
Digital Input F
5
Ground Out
6
Unused 
7
Unused 
8
Digital Input E (Not available when Encoder module is present)
 and Analog Input 4
9
2A Digital Output C (same as pin 1)
10
Analog Input 2
11
Analog Input 1
12
Analog Input 3
13
Ground Out
14
+5V Out (100mA max.)
15
Emergency Stop or Invert Switch input