Fujitsu MAM3184MC/MP Manual Do Utilizador

Página de 152
7 - 4
C141-E134-01EN
7.2.2
Sense data (3-0C-03), (4-40-xx), (4-44-xx), and (4-C4-xx)
Sense data (4-03-xx), (4-40-xx), (4-44-xx), and (4-C4-xx) indicate one of the following:
 
A target sector could not be detected using the sector counter.
 
A seek process overran the specified time.
 
A write to a disk terminated abnormally.
 
An error occurred in power-on self-diagnosis.
 
A hardware error occurred inside IDD.
 
A drive error occurred.
The symptoms above are generally caused by an error in a PCA or DE.
For details of the sense data above, refer to the SCSI Logical Interface Specifications.
7.2.3
Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00):  Disk read error
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk,
there is disk damage that was not recorded in the media defect list.  In this case, assign an alternate
block to the error-detected block using a REASSIGN BLOCKS command.  For an explanation of
the REASSIGN BLOCKS command, refer to the SCSI Logical Interface Specifications.
If this error occurs in different blocks, a PCA or DE is faulty.
For details of the above sense data, refer to the SCSI Logical Interface Specifications.
7.2.4
Sense data (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00):
SCSI interface error
Sense data (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00)
indicates one of the following symptoms:
 
An invalid or unsupported command was issued, or invalid or unsupported parameters were
specified.
 
A SCSI interface error occurred.
 
A parity error occurred in the SCSI bus.
If this error occurs, a PCA or the SCSI interface cable is faulty.
For details of the above sense data, refer to the SCSI Logical Interface Specifications.