ACR Electronics 3940.1 Manual Do Utilizador

Página de 11
Y1-03-0165 Rev. D 
2.3 
Disassembly 
This will ordinarily be required only  if testing shows that  the  light is malfunctioning, or if battery replacement is required. 
Recommended interval for battery replacement is one year. 
 
A. 
Hold the unit on a flat, firm surface, lens side up. Depress the top cap of the unit, by pushing straight down on 
the top cap assembly, until the swivel locks may be turned outward, clear of the cap. 
 
B. 
Grip the light lens (using a clean cloth or gloves for a better grip on the smooth surface and to avoid marring 
the lens surface) and pull upwards until the top cap is clear of the case. 
 
C. 
Turn the unit on its side, open end slightly downwards, to allow the foam filler and battery to slide out. 
 
D. 
Disconnect the battery by unscrewing the terminals from the battery posts. 
 
E. 
Replace the strobe module, if required, as follows: 
 
a.  Remove foam filler from strobe module, by sliding it off. 
 
b.  Slip foam spacer over new strobe module to seat in cap recess. 
 
c.  Inspect O-Ring seal for proper fit. Lubricate with silicone grease. 
 
F. 
Replace the battery by securing the two terminals to the battery posts. Assure tightness. 
 
NOTE: Connect black lead to center (-) post of battery. Connect red lead to outer (+) post of battery. 
 
G. 
Check  for  proper  operation  by  holding  the  top  cap  assembly  vertical  (light  lens  up).  The  unit  should  flash 
about once each second. If the unit does not operate, check for proper battery connection.   
 
2.4 
Assembly 
A.  Hold the case horizontally and slide the battery in, terminal end up (towards the open end of the case). 
 
B.  Lubricate the top cap O-ring with silicone grease and insert the cap and foam spacer into the case. 
 
C.  Place the unit upright on a firm surface, and press the top cap assembly until the cap slips into the case. 
 
D.  Depress the cap until the locking swivels can seat into the provided recesses. 
 
E.  Turn the locking swivels, seat them into the cap recesses and remove pressure from the top to allow it to move 
upwards and lock. 
 
F.  Check unit operation. 
 
CAUTION: Assure that the locking swivels are properly seated in the cap grooves. Rotate the cap, if necessary, to assure 
proper seating of the swivels.