Raymarine DS400 & DS500 Manual Do Utilizador

Página de 96
Chapter 2: Installation
13
2.6 System Connections
The rear of the display unit provides the following connection sockets:
Transducer connection.
Power, for 12 VDC power connection and NMEA connection. 
            
Figure 2-5:
DS400/500 Connector Panel
The following sections detail the connectors used when installing the 
DS400/500.
DC Power Connection
The DS400/500 is intended for use on the boat’s DC power systems rated 
from 10-18 Volts DC (13.8V nominal).
The power connection to the unit should be made at either the output of the 
battery isolator switch, or at a DC power distribution panel. Raymarine 
recommends that power is fed directly to the DS400/500 via its own 
dedicated cable system. 
A 2 amp, fast blow fuse is attached (in-line) to the red (positive) wire.
A 5 ft (1.5 m) Power/NMEA cable is supplied for connecting the boat’s DC 
power to the unit. The Power/NMEA cable may be extended by up to 60 ft 
(20 m) using a wire gauge of AWG 12 or greater.
DC power is connected at the seven-pin Power/NMEA connector on the 
unit’s connector panel. The connector (viewed from the outside) and pin 
functions are shown in the following diagram and table.
            f
D6459-1
Power/NMEA
Transducer
D6462-1
pin1