Hitachi SJ700 Manual Do Utilizador

Página de 40
OPERATION and PROGRAMMING
Press          
until               appears.
(1)   or the value previously 
  monitored is displayed.
(2)Function code appears.
(3)            appears.
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Power on
Press          key.
Press          key.
FUNC
FUNC
FUNC
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
機能
FUNC
記憶
STR
機能
FUNC
記憶
STR
機能
FUNC
記憶
STR
(4)Preset value is displayed.
(5)Newly set value is displayed.
(6)Returns to               and  
  the setting is complete.
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Hz
V
A
%
POWER
ALARM
RUN
PRG
kW
Press            
to set desired value.
Press          key
to store the value.
*To run the motor, go back to
 monitor mode or basic setting mode.
STR
機能
FUNC
記憶
STR
機能
FUNC
記憶
STR
機能
FUNC
記憶
STR
The contents of a basic mode display.
Setting the output frequency
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
 Display  code
d001 to d104
F001
F002
F003
F004
A001
A002
A003
A004
A005
A020
A021
A022
A023
A044
A045
A085
b001
b002
b008
b011
b037
b083
b084
b130
b131
C021
C022
C036
 Item
Monitor display
Output frequency setting
Acceleration (1) time setting
Deceleration (1) time setting
Operation direction setting
Frequency source setting
Run command source setting
Base frequency setting
Maximum frequency setting
[AT] selection
Multi-speed frequency setting
Multi-speed 1 setting
Multi-speed 2 setting
Multi-speed 3 setting
1st control method
V/f gain setting
Operation mode selection
Selection of restart mode
Allowable under-voltage power failure time
Retry-after-trip selection
Retry wait time after trip
Function code display restriction
Carrier frequency setting
Initialization mode selection
Selection of overvoltage suppression function
Setting of overvoltage suppression level
Setting of intelligent output terminal 11
Setting of intelligent output terminal 12
Alarm relay active state
SJ700/SJ700D and SJ700B Series can be easily operated with the digital operator provided as standard. The digital operator can 
also be detached and can be used for remote mounted control. Operator with copy function (WOP) and digital operator with 
potentiometer are also available as options.
Shows drive status.
Press to run the motor.
Press to stop the drive or 
reset an alarm.
Lights when the power input 
to the drive is ON.
Indicates the unit associated 
with the parameter display.
Press to write the new value 
to the EEPROM.
Press up or down to sequence 
through parameters and functions 
shown on the display, and 
increment/decrement values.
Press to set or monitor a 
parameter value.
Parameter Display
Power LED
Display Unit LEDs
Lights to indicate that the 
inverter has tripped.
ALARM LED
Store Key
Up/Down Keys
Monitor LEDs
Lights up when the inverter 
is ready to respond to the 
RUN key.
RUN key enable LED
RUN Key
STOP/RESET Key
Function Key
Displays frequency, motor current, 
rotational speed of the motor, and 
an alarm code.
If a desired parameter is not displayed, 
check the setting of function "b037" 
(function code display restriction). 
To display all parameters, specify "00" for "b037".
13