TERMINALS
Terminal Description
Symbol
Name
Explanation of Terminals
Ratings
Maximum capacity of relays   
AL1-AL0: AC 250V,  2A (R load)/0.2A (L load)  
 
DC 30V,   8A (R load)/0.6A (L load)
AL2-AL0: AC 250V,  1A (R load)/0.2A (L load)
 
DC 30V,   1A (R load)/0.2A (L load)
Minimum capacity of relays
AL1-AL0, AL2-AL0: 
AC100V, 10mA  DC5V, 100mA
Power Supply
Frequency Setting
Monitor Output
Monitor Output
Power Supply
Run 
Command
Functions
Common 
Terminal
State
Sensor
State/
Alarm
Common Terminal for Analog 
Power Source
Power Source for Frequency 
Setting
Frequency Command Terminal
Frequency Command Extra 
Terminal
Frequency Command Terminal
Analog Output Monitor (Voltage)
Analog Output Monitor (Current)
Digital Monitor (Voltage)
Power Terminal for Interface
Allowable input voltage range
Analog
Digital
Analog
Digital
In default setting, an alarm is activated when inverter output is turned off by a 
protective function. 
Common terminal for H, O, O2, OI, AM, and AMI. Do not ground.
-
,QSXWLPSHGDQFHNї$OORZDEOH
input voltage range: DC -0.3-+12V
DC 10V, 20mA max.
,QSXWLPSHGDQFHNї$OORZDEOH
input voltage range: DC 0-±12V
Maximum frequency is attained at DC 10V in DC 0-10V range. Set the voltage at 
A014 to command maximum frequency below  DC 10V.
O2 signal is added to the frequency command of O or OI in DC 0-±10V range. By 
changing configuration, frequency command can be input also at O2 terminal.
Maximum frequency is attained at DC 20mA in DC 4-20mA range. 
When the intelligent terminal configured as AT is on, OI signal is enabled.
Selection of one function from: 
Output frequency, output current, torque, output voltage, input power, electronic 
thermal load ratio, and LAD frequency.
[DC0-10V output (PWM output)]
Selection of one function from: Output frequency, output current, torque, output 
voltage, input power, electronic thermal load ratio, and LAD frequency.
[Digital pulse output (Pulse voltage DC 0/10V)]
Outputs the value of output frequency as digital pulse (duty 50%)
Internal power supply for input terminals. In the case of source type logic, 
common terminal for contact input terminals.
Common Terminal for Interface
Common terminal for P24, TH, and FM. In the case of sink type logic, common 
terminal for contact input terminals. Do not ground.
Select sink or source logic with the short-circuit bar on the control terminals.                          
Sink logic: Short P24 to PLC / Source logic: Short CM1 to PLC. 
When applying external power source, remove the short-circuit bar and connect 
PLC terminal to the external device.
Assign 5 functions to open collector outputs.
When the alarm code is selected at C062, terminal 11-13 or 11-14 are reserved 
for error codes of inverter trip.
(Refer to the standard specifications for the functions.)
Both sink and source logic are always applicable between each terminal and CM1.
The inverter trips when the external thermistor detects abnormal temperature. 
Common terminal is CM1.           
[Recommended thermistor characteristics]           
Allowable rated power: 100mW or over. 
,PSHGDQFHLQWKHFDVHRIDEQRUPDOWHPSHUDWXUHNї
1RWH7KHUPDOSURWHFWLRQOHYHOFDQEHVHWEHWZHHQDQGї
Forward Command Input
Intelligent Input Terminals
Common Terminal for 
Intelligent Input Terminals,
Common Terminal for 
External Power Supply for 
PLCs, etc.
Intelligent Output Terminals
Common Terminal for 
Intelligent Output Terminals
Thermistor Input Terminals
Alarm Output Terminals
Power supply for frequency command input
,QSXWLPSHGDQFHї$OORZDEOH
input voltage range: DC 0-24mA
DC 0-10V, 2mA max.
'&P$їPD[
Digital output frequency
 range: 0-3.6kHz, 1.2mA max.
DC 24V, 100mA max.
The motor runs forward when FW terminal is ON,
and stops when FW is OFF.
[Input ON condition]
Voltage between each terminal 
and PLC: DC 18V min.
[Input OFF condition] 
Voltage between each terminal 
and PLC: DC 3V max.
Input impedance between each 
WHUPLQDODQG3/&ї
Allowable maximum voltage 
between each terminal and 
PLC: DC 27V
Decrease in voltage between 
each terminal and CM2: 
4V max. during ON
Allowable maximum voltage: DC 27V
Allowable maximum current: 50mA
Common terminal for intelligent output terminal 11-15.
11
12
13
14
15
AL0
AL1
AL2
1
2
3
4
5
6
7
8
O2
OI
AM
AMI
FM
TH
L
H
-
P24
CM1
FW
PLC
CM2
O
Assign 8 functions to terminals.
(Refer to the standard specifications for the functions.)
DC0-8V
DC8V
[ Input Circuit]
Thermistor
TH
CM1
Control Circuit Terminals
Terminal Arrangement
Relay Output PCB (L300PTM)
L300PTM is available in case a relay output function is necessary.
H
L
O2
O
AM
OI
FM
AM1
TH
P24
FW
PLC
8
CM1
CM1
7
5
6
3
4
1
2
14
15
13
CM2
11
12
AL1
AL0 AL2
Screw diameter:M3
Terminal Width:6.4mm
Contact 
Input
Open 
Collector 
Output
Analog 
Input
Relay 
Output
Terminal Symbol
Specifications
11A
11C
12A
12C
Contacting Maximum Rate
Contacting Minimum Rate
AC250V
DC30A
DC1V
5A
1A
5A
1A
1mA
26