Vertex Standard FT-950 Manual Do Utilizador

Página de 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
127
Function: Programs a band to be skipped while selecting bands using the [CLAR/ 
VFO-B] knob. 
To program the band to be skipped, rotate the [CLAR/VFO-B] knob to recall the band 
to be skipped while selecting bands via the [CLAR/VFO-B] knob, then press the [ENT] 
button to change this setting to “ON” (a “d” notation will replace the “E” notation). 
Repeat the same procedure to cancel the setting (skipped “Off”: “d” notation appears). 
 
TX AUDIO Group 
091 TAUD EQ1 FRQ 
Function: Selects the center frequency of the lower range for the parametric 
microphone equalizer. 
Available Values: OFF/100 ~ 700 Hz (100 Hz/step) 
Default Setting: OFF 
OFF: 
The equalizer gain and Q-factor are set to factory defaults (flat). 
100 ~ 700: Center frequencies of 100 Hz ~ 700 Hz. 
You may adjust the equalizer gain and Q-factor at this selected audio frequency via 
menu items “092 TAUD EQ1 LVL” and “093 TAUD EQ1 BW.” 
 
092 TAUD EQ1 LVL 
Function: Adjusts the equalizer gain of the low range of the parametric microphone 
equalizer. 
Available Values: –10 ~ +10 
Default Setting: +5 
 
093 TAUD EQ1 BW 
Function: Adjusts the Q-factor of the low range of the parametric microphone equalizer. 
Available Values: 1 ~ 10 
Default Setting: 10 
 
094 TAUD EQ2 FRQ 
Function: Selects the center frequency of the middle range for the parametric 
microphone equalizer. 
Available Values: OFF/700 ~ 1500 Hz (100 Hz/step) 
Default Setting: OFF 
OFF: 
The equalizer gain and Q-factor are set to factory defaults (flat). 
700 ~ 1500:  Center frequencies of 700 Hz ~ 1500 Hz.