Electrical connection
 Ovens equipped with a three-pole power supply
cable are designed to operate with alternating
current at the voltage and frequency indicated on
the data plate located on the appliance (see below).
Fitting the power supply cable
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see  diagram).
2. Install the power
supply  cable  by
loosening the cable
clamp screw and the
three wire contact
screws L-N-
.
Connect the wires to
the corresponding
terminals: the Blue wire
to the terminal marked
(N), the Brown wire to
the terminal marked (L)
and the Yellow/Green
wire to the terminal
marked 
 (see diagram).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the electricity supply cable to the
mains
Install a standardised plug corresponding to the
load indicated on the data plate (see table).
The appliance must be directly connected to the mains
using an omnipolar switch with a minimum contact
opening of 3 mm installed between the appliance and
the mains.  The switch must be suitable for the charge
indicated and must comply with current electrical
regulations (the earthing wire must not be interrupted
by the switch). The supply cable must be positioned
so that it does not come into contact with temperatures
higher than 50°C at any point.
 The installer must ensure that the correct electrical
connection has been made and that it is fully
compliant  with  safety  regulations.
Before connecting the appliance to the power
supply,  make  sure  that:
• The appliance is earthed and the plug is compliant
with the law.
• The socket can withstand the maximum power of
the appliance, which is indicated on the data
plate  (see  below).
• The voltage is in the range between the values
indicated on the data plate (see below).
• The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
 Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily  accessible.
 The cable must not be bent or compressed.
 The cable must be checked regularly and replaced
by  authorised  technicians  only  (see  Assistance).
 The  manufacturer  declines  any  liability  should
these safety measures not be observed.
N
L
APPLIANCE SPECIFICATIONS 
Dimensions 
width 43.4 cm 
height 39.5 cm 
depth 40.8 cm 
Volume 
70 l 
Electrical 
connections 
voltage: 220 - 240 V~ 50Hz  
maximum power absorbed 
3400 W (see data plate) 
ENERGY 
LABEL 
Directive 2002/40/EC on the 
label of electric ovens. 
Standard EN 50304 
Declared energy consumption 
for Forced convection Class – 
heating mode: 
Gratin. 
 
This appliance conforms to the 
following European Economic 
Community directives: 
2006/95/EEC dated 12/12/06 
(Low Voltage) and subsequent 
amendments – 2004/108/EEC 
dated 15/12/04 
(Electromagnetic Compatibility) 
and subsequent amendments - 
93/68/EEC dated 22/07/93 and 
subsequent amendments. 
2002/96/EEC and subsequent 
amendments. 
1275/2008 stand-by/off mode.