Hotpoint SN56EX Manual Do Utilizador

Página de 12
3
GB
DATA PLATE 
Dimensions 
width cm 43.5 
height cm 32 
depth cm 41.5 
Volume 
lt. 58 
Dimensions of 
models with 
removable racks 
width cm 37.5 
height cm 32 
depth cm 41.5 
Volume of models 
with removable 
racks 
lt. 50 
Electrical 
connections 
voltage: 220-230V ~ 50/60 Hz or 
50Hz  (see data plate) 
maximum power absorbed 2250W
 
Directive 2002/40/EC on the label 
of electric ovens.  
Standard EN 50304 
ENERGY LABEL 
Energy consumption for Natural 
convection – heating mode:         
Convection mode 
 
Declared energy consumption for 
Forced convection Class – heating 
mode:         Multi-cooking 
 
This appliance conforms to the 
following European Economic 
Community directives:  
- 2006/95/EEC of 12/12/06 (Low 
Voltage) and subsequent 
amendments; 
-89/336/EEC of 03/05/89 
(Electromagnetic Compatibility) and 
subsequent amendments; 
- 93/68/EEC of 22/07/93 and 
subsequent amendments. 
- 2002/96/EC 
 
Electrical  connection
The electrical connection to the mains must be made
on the appliance.  The power voltage and frequency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
• Using a screwdriver, press on the tabs situated
on each side of the terminal board cover.
• Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
_ Unscrew the cable clamp screw and the contact
screws L-N-$.
• Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green $
• Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical  Connection:
Voltage Frequency: 230
V-1+N  50Hz
Fuse Section: 16A
Supply  cable:
3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly  dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal
board.
4
2
N
L
Electrical Connection