Installation 
2.3  Failsafe Output Wiring 
The Failsafe output relay is provided via a Phoenix connector to signal critical error 
conditions that may occur on the unit. The contacts are energized upon power up of 
the unit and remain energized until a critical alarm condition or power loss occurs. A 
common application for this output is to signal an alarm in the event of power failure. 
 
back
front 
Figure 7: Failsafe Output Relay 
 
Pin 
Function 
Normally Closed 
Normally closed (no power or critical 
alarm condition) 
Common 
Common relay contact 
Normally Open 
Normally open (no power or critical 
alarm condition) 
Table 4: Failsafe Output Relay Pinout 
 
 
Normally Closed 
Rat
ings
:
12
-2
4
V
, 2
A
P1
+
P1-
GND
P2-
P2+
Normally Open 
Common
RuggedSwitch™
i800 family 
13 