RuggedCom I800 Manual Do Utilizador

Página de 21
Technical Specifications 
3 Technical Specifications 
3.1  Type Test Specifications 
IEC 61000-6-2 EMC: Generic Standards - Immunity for industrial environments 
Test 
Description 
Levels 
Enclosure Contact 
+/- 4kV 
IEC 61000-4-2 
ESD 
Enclosure Air 
+/- 8kV 
IEC 61000-4-3 
Radiated RFI 
Enclosure ports 
10 V/m, 80 to 1000Mhz 
Signal ports 
+/- 1kV @ 5kHz 
IEC 61000-4-4 
Burst (Fast 
Transient) 
DC Power ports 
+/- 1kV @ 5kHz 
Signal ports 
+/- 1kV line-to-earth/line 
IEC 61000-4-5 
Surge 
DC Power ports 
+/- 0.5kV line-to-line 
+/- 1kV line-to-earth 
Signal ports 
DC Power ports 
IEC 61000-4-6 
Induced 
(Conducted) RFI 
Earth ground ports 
10V @ 0, 5-80 MHz 
IEC 61000-4-8 
Magnetic Field 
Enclosure ports 
30 A/m @ 50, 60 Hz 
IEC 61000-4-11 
Voltage Dips 
DC Power ports 
30% reduction for 0.5 period 
Signal ports 
IEC 61000-4-12 
Damped Oscillatory 
DC Power ports 
1kV common mode 
0.5kV differential mode 
Signal ports 
IEC 61000-4-16 
Mains Frequency 
Voltage 
DC Power ports 
10V continuous 
100V for 1s 
IEC 61000-4-17 
Ripple on D.C. 
Power Supply 
DC Power ports 
10% 
Table 7: Electromagnetic Compatibility tests 
 
IEC Environmental Type Tests  
Test  
Description  
Test Levels  
IEC 60068-2-1  
Cold Temperature  
Test Ad  
-40°C, 16 Hours  
IEC 60068-2-2  
Dry Heat  
Test Bd  
+85°C, 16 Hours  
IEC 60068-2-30  
Humidity (Damp 
Heat, Cyclic)  
Test Db  
95% (non-condensing), 55°C , 6 
cycles  
IEC 60255-21-1  
Vibration  
Tests Fc  
1g @ (10 - 500) Hz  
IEC 60255-21-2  
Shock  
Tests Ea  
30g @ 11mS  
Table 8: Environmental Type Tests 
RuggedSwitch™
i800 family 
17 
RuggedCom®