48 Chapter 3 Option card and DIMM installation
NN46110-316 03.01
Shutting down the system to add or replace hardware
To install or replace an option card or a DIMM, you must first shut down the VPN 
Router 1750 and unplug it.
To shut down the VPN Router 1750, perform the following steps:
1
Use the Web graphical user interface (GUI) or the command line interface 
(CLI) to shut down the gateway.
Web GUI: Choose AdminShutdown. Select the option to turn off the 
gateway after shutdown.
OR
CLI: Use the 
reload
 command to shut down the system. For example, 
enter 
reload power-off disable-logins “Upgrade hardware”
For more information about the 
reload
 command, see Nortel VPN 
Router Using the Command Line Interface (NN46110-507).
2
Wait for the system to shut down.
3
Disconnect the power cord from the power outlet, and then disconnect the 
power cord from the VPN Router 1750.
The power receptacle is on the rear of the VPN Router 1750 (see 
).
Warning: Risk of electric shock
Before you attempt to add or replace an option card or DIMM, shut 
down the VPN Router 1750 as described in this section.
Warning: Risk of electric shock
Make sure to turn off the VPN Router 1750 and unplug the power cord 
before you attempt to remove or install an option card or DIMM.