Bosch PB360S Manual Do Utilizador

Página de 40
12
Use of 12V Outlet
Note: Do not insert any device that pulls more than 1 Amp
or  else  the  fuse  will  open.    12V  outlet  will  not  operate
from battery pack.
1. Lift the rubber lid marked with 12V of the jack and insert
the plug of the device or the appliance.
2. Close  the  lid  as  soon  as  you  finish  using  the  outlet  to
prevent any other things from entering the jack.
3. If no power is available then check fuse.
Changing fuse
1. Unscrew fuse cap in counterclockwise direction.
2. Replace  fuse.  Replace  only  with  a  metric  5x20mm  fast
acting 1 Amp fuse (F1AL 250V).
3. Tighten fuse cap assembly in clockwise direction.
Do  not  bypass  the  fuse  or  use  any  other
fuse  except  what  is  specified,  as  it  may
cause damage to the unit.
Changing Clock Batteries
1. Open battery bay door.
2. Remove AA battery cover.
3. Remove old batteries and dispose of properly.
4. Insert  new  AA  batteries.    Do  not  use  mismatched
batteries, use only new Alkaline batteries.
12V
AUX 1
IN
LINE
OUT
250V
1AMP
FUSE
FOR 12V
OUTLET
USB
SD / MMC
AUX 1 IN
LINE OUT
Problem
Checkpoint
Remedy
Audio Unit doesn’t
1. Is power cord properly connected ?
1. Plug in AC power cord.
function.
2. Is the Bosch battery pack installed or
2. Make sure battery is completely inserted. 
inserted properly?
3. Does the battery need charging?
3. Plug in power cord and insert battery.
It is noisy or weak
1. Is there any facility interfering with 
1. Move unit to new location away from
in radio receiving.
the unit.
interference.
2. Is there any interference to the
2. Turn the unit in different directions.
internal FM antenna?
12V DC outlet
1. Is 1 amp fuse properly inserted?
1. Insert 1 amp fuse.
doesn’t function
2. Has the 1 amp fuse blown open?
2. Replace fuse.
4-Way Power outlet 
1. Is power cord properly connected?
1. Plug in AC power cord.
does not function
2. Is green light illuminated on outlets?
Does unit suddenly
1. Is power cord properly connected
1. Plug in power to unit.
fail to work
to unit?
2. Is the LCD displaying that there is
2. Software in unit needs to be reset. Remove all
power to the unit?
batteries from unit and unplug AC power cord, wait   
for 30 seconds and reconnect AC power cord.
Trouble Shooting Guide
REPLACE AA BATTERY
WHEN UNIT NO LONGER
KEEPS CORRECT TIME
LOCATION OF AA
BATTERIES
WARNING
!