Vidikron Vision 10 Manual Do Utilizador

Página de 74
52
Vidikron Vision Model 10/Model 12 Owner’s Operating Manual
PRE
L
IMINAR
Y
5.6 
Lamp Replacement
1.
Turn off the projector and wait for the cooling fan to stop. 
2.
Unplug the power cord. Allow the projector to cool down for approximately one hour 
prior to removing the lamp assembly for replacement.
3.
Loosen the two captive 
lamp cover screws and 
remove the cover.
 
 
 
 
 
 
 
 
 
 
4.
Loosen the four lamp 
assembly mounting screws.
5.
Grasp the lamp assembly 
handle and pull gently, 
removing the lamp module 
from the projector housing. 
As you do so, the lamp 
cooling interlock switch on 
the inside of the lamp cavity 
(near the top) moves to the 
OFF position. 
 
 
6.
Gently slide the new lamp assembly into the lamp cavity. Align the two power 
connectors at the top of the lamp assembly with the two sockets at the top of the lamp 
cavity. Press gently on both sides of the lamp assembly to snap it into place. As you do 
so, the lamp cooling interlock switch returns to the ON position.
7.
Tighten the lamp assembly mounting screws. 
8.
Replace the lamp cover and secure the captive lamp cover screws.
9.
Plug in the projector and turn it on. 
10. Reset the Lamp Timer to zero. To do this, select Lamp Timer Reset from the ISF 
Calibration menu and press ENTER. The Vision 10/12 shows the number of hours the 
projector lamp has been in service and asks you to confirm or cancel the reset. Press 
ENTER again to confirm.