Manual Do Utilizadoríndice analíticoContents5A.1 Notification Appliances A-111A.2 Two-Wire Smoke Detectors A-1211B.1 Characters used for Naming B-111Section 1 Introduction131.1 Overview of Basic System131.1.1 Hardware Features131.1.2 Software Features141.2 About this Manual141.2.1 Terms Used in this Manual141.3 Compatible Products151.4 How to Contact Silent Knight16Section 2 Agency Listings, Approvals, and Requirements212.1 Federal Communications Commission (FCC)212.2 Underwriters Laboratories (UL)222.2.1 Requirements for All Installations222.2.2 Requirements for Central Station Fire Alarm Systems232.2.3 Requirements for Local Protected Fire Alarm Systems232.2.4 Requirements for Remote Station Protected Fire Alarm Systems - Digital Alarm Communicator Transmitter (DACT)23Section 3 Before You Begin Installing253.1 What’s in the Box?253.2 Environmental Specifications253.3 Electrical Specifications263.4 Wiring Specifications273.5 Board Assembly Diagram293.6 Calculating Current Draw and Standby Battery303.6.1 Current Draw Worksheet Requirements303.6.2 Current Draw Worksheet for SK SLC Devices313.6.3 Current Draw Worksheet for Hochiki SLC Devices343.6.4 Maximum Battery Standby Load363.7 Installation Tasks Overview36Section 4 Control Panel Installation394.1 Mounting the Control Panel Cabinet394.1.1 Preventing Water Damage394.1.2 Removing the 5820XL Assembly from the Housing394.2 AC Connection404.3 Battery Connection414.3.1 RBB Accessory Cabinet424.3.1.1 Installing the RBB Accessory Cabinet and Batteries424.4 SBUS Wiring444.4.1 Calculating Wiring distance for SBUS modules444.4.2 Wiring Configurations474.5 Remote Annunciator 5860 Installation484.5.1 Mounting the 5860494.5.1.1 Flush Mounting504.5.1.2 Surface Mounting524.5.2 Model 5860 Connection to the Panel534.6 5815XL Installation544.6.1 5815XL Connection to the Panel554.7 5824 Serial/Parallel Interface Module Installation564.7.1 Selecting 5824 Options574.8 5880 LED I/O Module594.8.1 5880 Board Layout594.8.2 FACP Connection604.8.3 LED Wiring614.8.4 Dry Contact Wiring624.9 5865-3 / 5865-4 LED Annunciator Installation634.9.1 FACP Connection644.9.2 5865 Mounting654.10 Configuring Modules664.10.1 Assigning Module IDs664.11 Telephone Connection674.12 5211 Ground Start Relay674.13 Flexputs™ I/O Circuits684.13.1 Conventional Notification Appliance684.13.1.1 Regulated Class B Notification Wiring684.13.1.2 Class A Notification Wiring704.13.2 Conventional Input Switch Circuits714.13.2.1 Class B Inputs714.13.2.2 Class A Inputs724.13.3 Installing 2-Wire Smoke Detectors734.13.3.1 Installing 2-Wire Class B Smoke Detectors734.13.3.2 Installing 2-Wire Class A Smoke Detector744.13.4 Installing 4-Wire Smoke Detectors754.13.4.1 Installing a Class B 4-Wire Smoke Detector754.13.4.2 Installing 4-Wire Class A Smoke Detectors764.13.5 Auxiliary Power Installation774.13.5.1 Door Holder Power774.13.5.2 Constant Power774.13.5.3 Resettable Power784.14 On-Board Relays (Conventional)784.14.1 Trouble Relay784.14.2 Programmable Relays784.15 Remote Station Applications794.15.1 Keltron Model 3158 Installation794.15.2 City Box Connection Using the 5220 Module804.15.3 NFPA 72 Polarity Reversal814.15.3.1 Using the 5220 Module814.15.3.2 Using the 7644 Module824.15.4 Using the SD500-ARM Addressable Relay Module834.15.5 Using a MR-201/T Control Relay From Air Products844.15.6 Transmitter Activated by Dry Contacts85Section 5 Hochiki and SK SLC Device Installation875.1 List of SK SLC Devices875.2 List of Hochiki SLC Devices885.3 Maximum Number of Devices895.4 Wiring Requirements for SLC Devices895.4.1 Wiring 5815XL in Style 4 (Class B) Configuration895.4.2 Wiring 5815XL in Style 6 & 7 (Class A) Configuration915.5 Wiring SK SLC Detectors925.6 Addressing SK SLC Devices935.7 Hochiki Detector Installation945.7.1 Wiring Hochiki Detectors945.8 Addressing Hochiki Devices955.8.1 SD505-APS, SD505-AHS, & SD505-AIS955.8.2 SLC Devices with Dip Switches96Section 6 Programming Overview976.1 JumpStart Autoprogramming976.1.1 Input Points986.1.2 Output Points986.1.3 Running JumpStart986.2 Mapping Overview1006.2.1 Input Point Mapping1016.2.2 Output Circuit Mapping1026.2.3 Zone Event Mapping1036.2.4 Mapping LED Points1056.3 Programming Using the 5660 Silent Knight Software Suite1066.4 Programming Using an Annunciator1066.4.1 Entering & Exiting the Program Menu1076.4.1.1 Moving through the Menus1076.4.1.2 Selecting Options and Entering Data1086.4.1.3 Editing Keys1086.5 Programming Menu Quick Reference109Section 7 Programming1177.1 UL 864 Programming Requirements1177.2 SLC Family1187.3 Modules1187.3.1 Edit Modules1197.3.1.1 Naming Modules1197.3.1.2 Setting the 5815XL Wiring Class1207.3.2 Adding a Module1207.3.3 Deleting a Module1217.4 Zone1217.4.1 Edit Zone1217.4.1.1 Edit Zone Name1227.4.1.2 Edit Zone Properties1227.4.1.3 Zone Outputs1247.4.1.4 Cadence Patterns1277.4.1.5 Zone Accessory Options1277.4.2 Add Zone1287.4.3 Delete Zone1287.4.4 View Zone Points1297.5 Group1307.5.1 Edit Group1307.5.1.1 Edit Group Name1307.5.1.2 Edit Group Properties1317.5.2 Add Group1337.5.3 Delete Group1337.5.4 View Group Points1347.5.5 Edit Output Group Templates1347.6 Point1357.6.1 Point Programming For 5815XL Module1357.6.2 Point Programming For Internal or External Power Module (5895XL)1407.6.3 Point Programming For 5880 and 5865 Modules1427.6.3.1 Assigning a Name to Points1437.7 System Options1437.7.1 Reporting Account1447.7.1.1 Edit Accounts1457.7.1.2 Auto Test Time1487.7.2 Phone Lines1487.7.2.1 Dialing Prefix1497.7.2.2 Number of Answer Rings1507.7.2.3 Dial Option (TouchTone or Pulse)1507.7.2.4 Rotary Format1507.7.2.5 Line Monitor1507.7.2.6 Ground Start Relay1507.7.2.7 Answering Machine Bypass1517.7.3 Sys. Event Outputs1517.7.3.1 Trouble Events1527.7.3.2 System Alarm Cadence1537.7.4 Miscellaneous Options 11547.7.4.1 Water Flow Delay1547.7.4.2 Low AC Report Delay1567.7.4.3 Automatic Daylight Savings Adjustment1567.7.4.4 Clock Display Format (AM/PM or Military)1567.7.4.5 Change AC Line Frequency1567.7.5 Miscellaneous Options 21577.7.5.1 Synchronize Strobes Active During Silence1577.7.5.2 Auto Display Oldest Event1577.7.5.3 Report by Zone or by Point1577.7.6 Miscellaneous Options 31587.7.6.1 Alarm Verification Time1587.7.6.2 Plex Door Option1587.7.6.3 Daylight Saving Time Start and End1597.7.7 Edit Banner Message1607.8 JumpStart Autoprogramming1617.9 Computer Account1627.10 Access Codes1637.10.1 Profile Edit Menu1647.10.1.1 Edit Name1647.10.1.2 Edit Access Code1647.10.1.3 Panel Functions164Section 8 System Operation1658.1 User and Installer Default Codes1658.2 Annunciator Description1658.2.1 LCD Displays1668.2.2 Banner1668.3 Key Operation1668.4 Menu System1678.4.1 Main Menu Overview1678.4.2 Using the Menus1688.5 Basic Operation1688.5.1 Setting Time and Date1688.5.2 Disable / Enable a Point1688.5.3 Disable / Enable NACs by Group1688.5.4 View Event History1698.5.4.1 To clear the event history1698.5.5 Conduct a Fire Drill1698.5.6 Conduct an Indicator Test1698.5.7 Conduct a Walk Test1708.5.8 Conduct a Dialer Test1708.5.9 Silence alarms or troubles1718.5.10 Reset alarms1718.5.11 Check Detector Through Point Status1718.5.12 View Status of a Point1728.5.13 View Alarms or Troubles1728.5.14 View System Information1728.5.15 Reset dialer1728.5.16 Communicating with a Remote Computer1738.5.17 Working with a Printer1748.6 Operation Mode Behavior1758.7 Releasing Operations1788.7.1 Single Interlock Zone Releasing1798.7.2 Double Interlock Zone Releasing1808.8 Smoke Alarm Verification181Section 9 Reporting1839.1 Receivers Compatible with the Control Panel1839.2 Reporting Formats Dialer Outputs183Section 10 Testing and Troubleshooting19110.1 Troubleshooting19110.2 Common Problems19110.2.1 Periodic Testing And Maintenance19210.2.2 Event History19310.3 Built-in Troubleshooting and Testing Tools19410.3.1 SLC Device Locator19410.3.2 SLC Multi Locator19510.3.3 I/O Point Control19610.3.4 Earth Fault Resistance197Section 11 Installation Records19911.1 SLC Point Record19911.2 Conventional Output Point Record206Appendix A Compatible Devices207Appendix B Special Characters Lists221Silent Knight Fire Product Warranty and Return Policy223Tamanho: 6 MBPáginas: 228Language: EnglishAbrir o manual