Manual Do Utilizador (DBS2400GP4)índice analítico1. Introduction1Chapter Outline1Server Board Use Disclaimer12. Overview2Intel® Server Boards S2400GP Feature Set2Table 1. Intel® Server Boards S2400GP Feature Set2Server Board Layout4Server Board Connector and Component Layout4Figure 1. Intel® Server Board S2400GP Layout (S2400GP4 as example)4Figure 2. Intel® Server Board S2400GP Components5Table 2. Intel® Server Boards S2400GP Components6Server Board Mechanical Drawings7Figure 3. Major Board Components7Figure 4. Intel® Server Board S2400GP – Mounting Hole Locations (1 of 2)8Figure 5. Intel® Server Board S2400GP – Mounting Hole Locations (2 of 2)9Figure 6. Intel® Server Boards S2400GP – Major Connector Pin-1 Locations (1 of 3)10Figure 7. Intel® Server Boards S2400GP – Major Connector Pin-1 Locations (2 of 3)11Figure 8. Intel® Server Boards S2400GP – Major Connector Pin-1 Locations (2 of 3)12Figure 9. Intel® Server Boards S2400GP – Primary Side Keep-out Zone13Figure 10. Intel® Server Boards S2400GP – Primary Side Card Side Keep-out Zone14Server Board Rear I/O Layout15Figure 11. Intel® Server Boards S2400GP – Second Side Keep-out Zone15Figure 12. Intel® Server Boards S2400GP Rear I/O Layout163. Functional Architecture17Processor Support17Figure 13. Intel® Server Board S2400GP Functional Block Diagram17Processor Socket Assembly18Processor Population rules18Figure 14. Processor Socket Assembly18Table 3. Mixed Processor Configurations19Processor Function Overview22Intel® QuickPath Interconnect23Integrated Memory Controller (IMC) and Memory Subsystem233.6.1 Supported Memory24Table 4. UDIMM Support Guidelines24Table 5. RDIMM Support Guidelines25Table 6. LRDIMM Support Guidelines253.6.2 Memory population rules26Table 7. Intel® Server Board S2400GP DIMM Nomenclature26Figure 15. Intel® Server Board S2400GP DIMM Slot Layout273.6.3 Publishing System Memory283.6.4 RAS Features29Processor Integrated I/O Module (IIO)333.7.1 Network Interface34Figure 16. Functional Block Diagram of Processor IIO Sub-system34Intel® C600-A Chipset Functional Overview35Table 8. External RJ45 NIC Port LED Definition35Figure 17. Functional Block Diagram – Chipset Supported Features and Functions363.8.1 Digital Media Interface (DMI)373.8.2 PCI Express* Interface373.8.3 Serial ATA (SATA) Controller373.8.4 AHCI373.8.5 Rapid Storage Technology373.8.6 PCI Interface383.8.7 Low Pin Count (LPC) Interface383.8.8 Serial Peripheral Interface (SPI)383.8.9 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)383.8.10 Advanced Programmable Interrupt Controller (APIC)383.8.11 Universal Serial Bus (USB) Controller393.8.12 Gigabit Ethernet Controller393.8.13 RTC393.8.14 GPIO393.8.15 Enhanced Power Management393.8.16 Manageability403.8.17 System Management Bus (SMBus* 2.0)403.8.18 Intel® Active Management Technology (Intel® AMT)403.8.19 Integrated NVSRAM Controller413.8.20 Intel® Virtualization Technology for Direct I/O (Intel® VT-d)413.8.21 JTAG Boundary-Scan413.8.22 KVM/Serial Over LAN (SOL) Function41Table 9. Intel® RAID C600 Upgrade Key Options423.8.24 Intel® Embedded Server RAID Technology 2 (ESRT2)433.8.25 Intel® Rapid Storage Technology (RSTe)43Figure 18. Integrated Baseboard Management Controller (BMC) Overview44Super I/O Controller453.10.1 Keyboard and Mouse Support453.10.2 Wake-up Control45Graphics Controller and Video Support45Figure 19. Integrated BMC Hardware45Table 10. Video Modes45Baseboard Management Controller46Table 11. Video mode463.12.1 Remote KVMS Support473.12.2 Integrated BMC Embedded LAN Channel474 System Security49BIOS Password Protection49Trusted Platform Module (TPM) Support50TPM security BIOS504.3.1 Physical Presence514.3.2 TPM Security Setup Options514.3.3 Security Screen52Figure 20. Setup Utility – TPM Configuration Screen52Intel® Trusted Execution Technology53Table 12. TPM Setup Utility – Security Configuration Screen Fields535 Technology Support55Intel® Trusted Execution Technology55Intel® Virtualization Technology – Intel® VT-x/VT-d/VT-c55Intel® Intelligent Power Node Manager56Table 13. Intel® Intelligent Power Node Manager565.3.1 Hardware Requirements576 Platform Management Functional Overview58Baseboard Management Controller (BMC) Firmware Feature Support586.1.1 IPMI 2.0 Features586.1.2 Non IPMI Features596.1.3 New Manageability Features60Basic and Advanced Features61Table 14. Basic and Advanced Features61Integrated BMC Hardware: Emulex* Pilot III626.3.1 Emulex* Pilot III Baseboard Management Controller Functionality62Advanced Configuration and Power Interface (ACPI)63Table 15. ACPI Power States63Power Control Sources64BMC Watchdog64Table 16. Power Control Initiators64Fault Resilient Booting (FRB)65Sensor Monitoring65Field Replaceable Unit (FRU) Inventory Device66System Event Log (SEL)66System Fan Management666.11.1 Thermal and Acoustic Management676.11.2 Fan Profiles67Table 17. Fan Profiles686.11.3 Thermal Sensor Input to Fan Speed Control696.11.4 Memory Thermal Throttling70Figure 21. Fan Speed Control Process70Messaging Interfaces716.12.1 User Model716.12.2 IPMB Communication Interface71Table 18. Messaging Interfaces716.12.3 LAN Interface726.12.4 Address Resolution Protocol (ARP)786.12.5 Internet Control Message Protocol (ICMP)786.12.6 Virtual Local Area Network (VLAN)786.12.7 Secure Shell (SSH)796.12.8 Serial-over-LAN (SOL 2.0)796.12.9 Platform Event Filter (PEF)79Table 19. Factory Configured PEF Table Entries796.12.10 LAN Alerting806.12.11 Alert Policy Table806.12.12 SM-CLP (SM-CLP Lite)806.12.13 Embedded Web Server816.12.14 Virtual Front Panel836.12.15 Embedded Platform Debug846.12.16 Data Center Management Interface (DCMI)866.12.17 Lightweight Directory Authentication Protocol (LDAP)86Table 20. Diagnostic Data867 Advanced Management Feature Support (RMM4)88Figure 22. Intel® RMM4 Lite Activation Key Installation88Table 22. RMM4 Option Kits88Keyboard, Video, Mouse (KVM) Redirection89Figure 23. Intel® RMM4 Dedicated Management NIC Installation89Remote Console90Performance90Security91Availability91Usage91Force-enter BIOS Setup91Media Redirection91Availability92Network Port Usage928 On-board Connector/Header Overview93Board Connector Information93Table 23. Board Connector Matrix93Power Connectors94Table 24. Main Power Connector Pin-out94Table 25. CPU 1/CPU 2 Power Connector Pin-out94System Management Headers95Intel® Remote Management Module 4 Connector95Table 26. Power Supply Auxiliary Signal Connector Pin-out95Table 27. Intel® RMM4 Connector Pin-out95TPM connector96LCP Header96HSBP Header96SGPIO Header96Table 28. Intel® RMM4 – Lite Connector Pin-out96Table 29. TPM connector Pin-out96Table 30. LCP Header Pin-out96Table 31. HSBP_I2C Header Pin-out96Table 32. SGPIO Header Pin-out96Front Panel Connector97I/O Connectors97VGA Connector97NIC Connectors97Table 33. Front Panel SSI Standard 30-pin Connector Pin-out97Table 34. VGA Connector Pin-out97SATA Connectors98Serial Port Connectors98Table 35. RJ-45 10/100/1000 NIC Connector Pin-out98Table 36. SATA, MiniSAS SCU-0 and SCU-1 Connector Pin-out98Table 37. External DB9 Serial A Port Pin-out99Table 38. Internal 9-pin Serial B Header Pin-out99USB Connector100Table 39. External USB Connector Pin-out100Table 40. Internal USB Connector Pin-out100Table 41. Pin-out of Internal Low-Profile USB Connector for Solid State Drive100Fan Headers101Table 42. Internal Type A USB Port Pin-out101Table 43. SSI 4-pin Fan Header Pin-out101Table 44. SSI 6-pin Fan Header Pin-out1019 Jumper Blocks103Figure 24. Jumper Blocks (J1C2, J1C5, J1E2, J2H3, J3H3, J3H4, J3H5, J3H6)103Table 45. Server Board Jumpers (J1C2, J1E2, J1E4, J1E5, J1H1)103BIOS Default (CMOS Clear) and Password Clear Usage Procedure104Clearing CMOS (BIOS default)104Clearing the Password105Force BMC Update Procedure105ME Force Update Jumper106BIOS Recovery Jumper10610 Intel Light Guided Diagnostics1085 V Stand-by LED108Figure 25. 5 V Stand-by Status LED Location108Fan Fault LEDs109CPU Fault LEDs109Figure 26. Fan Fault LED Locations109System Status LED110Figure 27. CPU Fault LED Locations110Figure 28. System Status LED Location111Table 46. System Status LED112DIMM Fault LEDs113Post Code Diagnostic LEDs114Figure 29. DIMM Fault LEDs Location114Table 47. BMC Boot/Reset Status LED Indicators115Figure 30. POST Code Diagnostic LED Locations11611 Environmental Limits Specification117Processor Thermal Design Power (TDP) Support117Table 48. Server Board Design Specifications117MTBF118Server Board Power Distribution118Table 49. MTBF Estimate118Figure 31. Power Distribution Block Diagram119Appendix A: Integration and Usage Tips120Appendix B: BMC Sensor Tables121Table 50. Integrated BMC Core Sensors123Appendix C: POST Code Diagnostic LED Decoder129Figure 32. POST Code Diagnostic LEDs129Table 51. POST Progress Code LED Example130Table 52. POST Progress Codes130Table 53. MRC Progress Codes132Table 54. POST Progress LED Codes133Appendix D: POST Code Errors134Table 55. POST Error Codes and Messages135Table 56. POST Error Beep Codes138Table 57. Integrated BMC Beep Codes139Appendix E: Supported Intel® Server Chassis140Table 58. Intel® Server Chassis P4000M family140Glossary142Reference Documents146Tamanho: 4 MBPáginas: 156Language: EnglishAbrir o manual