TOA VS-900 Programmer’s Guide
9
2. Remote Dialing – All Call Paging
The data sequence below will remote dial Master Station #2 in Exchange #3 to initiate All-Call Paging by
dialing *800#. Again, the “CC” (Clear) is included to terminate any current Master Station functions.
Note: The total Dialing Contents must be 32 bytes.
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
VS-900MF to PC
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Remote Dial
1
4EH
Remote Dialing Request
Exchange #
2
30H 33H
EXCHANGE # "03"
Master Station #
1
32H
MASTER # "2"
Dialing Contents 32 Bytes 43H 43H 2AH 38H 30H 30H
23H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H
"CC*800#"
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
7DH
Block Check Character*
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
VS-900MF to PC
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
PC to VS-900MF