Page 7 
 
Certifications and compliances 
Safety 
  Designed to IEC 1010-1, UL3111-1 and CSA specifications 
  1000V DC Category II 
  600V DC Category III 
  750V AC Category II 
Input rating 
  600V AC Category III 
  CAT III: Distribution level mains, fixed installation. 
  CAT II: Local level mains, appliances, portable equipment. 
Over voltage category 
  CAT I: Signal level, special equipment or parts  
                 of equipment, telecommunication, electronics. 
Pollution Degree 2 
  Do not operate in environments where conductive Pollutants may be 
  present. 
EC Declaration of 
Conformity 
  Meets the intent of Directive 89/336/EEC for 
  Electromagnetic Compatibility and Low Voltage  
  Directive 73/23/EEC for Product Safety. Compliance was 
  demonstrated to the following specifications as listed in the 
  official Journal of the European Communities: 
  En 55011 Class A: Radiated and Conducted Emissions. 
  EN 50082-1 Immunity: 
                              IEC 801-2 Electrostatic Discharge 
                              IEC 801-3 RF Radiated 
  EN 61010-1   Safety requirements for electrical equipment 
                          for measurement, control, and laboratory use. 
 
 
 
Form Number TM61633-5 
Rev 5 Dec 2006