Electrical Requirements
70420801 (EN)
40
To Connect Electrical Service to the 
Tumble Dryer
NOTE: The wiring diagram is located in the 
junction or contactor box.
1. Install a circuit breaker as close to the tumble 
dryer as possible. If more than one tumble dryer 
is being installed, a circuit breaker should be 
provided for each. This will make it possible to 
disconnect each tumble dryer for maintenance 
purposes.
2. Connect conduit-encased leads to the circuit 
breaker. Connect wire leads to the appropriate 
labeled terminal on the terminal block. The 
ground wire must be connected to the ground 
connection as shown in Figure 12
3. Check the electrical service phase sequence 
(three phase only). If one of the power leads is a 
“high leg,” connect it to lead L3 in the tumble 
dryer. The cylinder must rotate clockwise and the 
fan must rotate counterclockwise (as viewed 
from the front of the tumble dryer – with selector 
switch in non-reverse position). If not, 
interchange leads L1 and L2 in the tumble dryer 
connection box.