Setting the aspect ratio for SD playback in 
HD mode
When outputting SD video down-converted from HD 
video, you can switch the aspect ratio.
(How to select an item in the menu screen: Turn the 
MENU knob to move the 
b mark to the desired item.)
1
Display the OUTPUT page of the OPERATION 
menu, and press the MENU knob.
2
Select HD
tSD(PLAY BACK), and press the MENU 
knob.
3
Turn the MENU knob to select the desired aspect ratio 
(16:9/4:3), and press the MENU knob.
The HD analog composite output from the PDW-F330 and 
the HDSDI output from the PDW-F350 are always of the 
aspect ratio of 16:9.
To display the aspect ratio of 16:9 on the 
viewfinder screen
When the recording format is DVCAM and the aspect ratio 
is 16:9, you can display the indication “16:9” on the 
viewfinder screen by setting DISP 16:9 on the VF DISP 1 
page of the OPERATION menu to ON.
About the CCD Scan Mode
This unit allows you to record in progressive scan mode as 
well as in interlace scan mode. You can select the scan 
mode from the following modes using the FORMAT page 
of the OPERATION menu.
• 60i (interlace scan) mode
• 30P (progressive scan) mode
• 23.98P mode
 
Pulldown method for DVCAM format recording in 23.98P mode
DVCAM video signals recorded in 23.98P mode are 2-3 
pulled down, and recorded on a disc as 60i signals.
.
Note
DF/NDF
Purpose
Notes
DF
Obtain an effect similar 
to that obtained by 
23.98P shooting while 
maintaining interlace 
scan mode.
NDF
Re-convert to 23.98P 
with nonlinear editing 
software (NLE).
(Select according to 
your NLE.)
• You can start recording at frame 0 or frame 5 of the timecode. Therefore, when setting 
the timecode or recording in backspace editing mode, the value of the least significant 
digit is limited to 0 or 5.
• There will be noise on the recorded image if you change the operating mode for the 
internal timecode generator using the F-RUN/SET/R-RUN switch on the side control 
panel while recording.
• The video and audio signal and timecode output via i.LINK may not be consecutive 
when recording starts.
Notes on 2-3 pulldown
• When the PRESET/REGEN/CLOCK switch on the side control panel is set to CLOCK, 
this unit operates in DF mode. The synchronization of the timecode and the pulled-
down picture is disabled.
• When drop-frame timecode is input via the TC IN connector, this unit operates in DF 
mode and synchronization of the pulled-down picture and the timecode is disabled. 
This setting will continue in effect until the timecode setting (F-RUN/R-RUN or DF/NDF) 