Recording – Advanced Operations
  
Ch
apt
er 3  Rec
o
rdi
ng and
 P
la
y
bac
k
Recording with the Clip Continuous 
Rec Function
Normally, a clip is generated as an independent file every 
time recording starts and stops. The Clip Continuous Rec 
function allows you to continue recording to the same clip 
until the function is turned off, regardless of how many 
times recording starts and stops. This is convenient if you 
want to avoid generating a large number of short clips, or 
if you want to record without worrying about the limit on 
the number of clips (maximum 300). A REC START 
essence mark is recorded whenever recording starts, which 
makes it easy to find the recording start points.
(How to select an item in the menu screen: Turn the 
MENU knob to move the 
b mark to the desired item.)
1
Set CLIP CONT REC on the SPECIAL EFFECTS 
page of the OPERATION menu to ON.
For details on menu operations, see “Basic Menu 
Operations” (page 129).
2
Select CLIP CONT REC, and press the MENU knob. 
3
Press the MENU knob. 
The VDR operation indicator in the viewfinder 
changes to “CONT”, and the Clip Continuous Rec 
function is enabled.
The Clip Continuous Rec ON/OFF function can be 
assigned to the ASSIGN 1/2/3/4 switches.
See “Assigning Functions to ASSIGN Switches” (page 
141) f
or more information about the ASSIGN switches.
The following recording modes cannot be enabled when 
this function is enabled. 
• Interval Rec function 
• Picture Cache function
To stop the function
Do one of the following to stop the Continuous Rec 
function. (A new clip will be generated the next time you 
start recording.)
• Perform a clip operation (lock or delete a clip)
• Make a network or FAM connection
• Eject the disc
• Change the recording format. (The unit responds as 
follows. If the FIND MODE on the ESSENCE MARK 
page of the MAINTENANCE menu is set to CLIP, the 
unit moves from the current position to the next clip. If 
it is set to R.ST, the unit moves from the current position 
to the next REC START essence mark.)
• Power the unit off
To turn the function off
Set CLIP CONT REC on the SPECIAL EFFECTS page of 
the OPERATION menu to OFF.
Note
 002 SPECIAL EFFECTS TOP
 SLOW&QUICK      :   OFF
 FRAME RATE      :   30P
 CLIP CONT REC   :    ON
 INTERVAL REC    :    ON
 INTERVAL TIME   :  1SEC
 NUMBER OF FRAME :    1F
 NUMBER OF TIMES :  CONT
 PRE-LIGHTING    :   OFF
 PICTURE CACHE   :   OFF
 CACHE REC TIME  : 8-10s