Справочник Пользователя для Sony PDW-530P

Скачать
Страница из 216
Cha
p
te
r 7  
 Men
u
 Dis
pla
y
s
 and
 Det
a
iled Se
tt
ing
s
138
7-3 Adjustments and Settings From Menus
7-3-9 Setting the CCD Scan Mode
Since the camcorder has CCDs that use an “all pixels read-
out method,” a progressive scan mode is also available in 
addition to the conventional interlace scan mode.
You can select either of the following modes using the 
FORMAT page of the OPERATION menu.
• I (interlace scan) mode
• PsF (progressive scan) mode
Installing the CBK-FC01 allows you to select the 24P 
mode.
Each mode is described below using timing charts.
I (interlace scan) mode
Interlace scan mode timing chart
The video signal of an odd scanning line and that of an 
even scanning line are output from the CCD alternately. 
Thus, the timing of the odd-field video signal and even-
field video signal are different.
PsF (progressive scan) mode
Progressive scan mode timing chart
The video signal of an odd scanning line and that of an 
even scanning line are output from the CCD at the same 
time. Then they are sent to the memory and separated into 
odd-field and even-field scanning lines. Thus the timing of 
an odd-field video signal and an even-field video signal are 
the same.
24P mode (2-3 pull-down) mode (PDW-510/530 only)
24P mode timing chart
After reading from the CCDs in 24P mode (23.98 frames 
per second), a pull-down conversion is carried out to the 30 
frames (29.97 frames per second) of the normal 
progressive scan mode.
CCD output
Video output signal
O: Odd 
E: Even
CCD output
Video output signal
O: Odd 
E: Even
A O
A ( O + E )
B ( O + E )
C ( O + E )
D ( O + E )
A ( O + E )
A E
B O
B E
B O
C E
C O
D E
D O
D E
A O
A E
CCD output
Video output signal
O: Odd 
E: Even
23.98 frames per second
29.97 frames per second