Справочник Пользователя для Sony XC-555
12
RS-232C Command List
XC-555/P
12 pin Connector
1
GND
2
+12 V
3
GND
4
VBS/Y out
5
GND
6
– /HD in
7
VS/VD in
8
GND
9
– /C out
10
TXD (RS-232C)
11
RXD (RS-232C)
12
GND
PC
D-SUB 9P
CD
1
RXD
2
TXD
3
DTR
4
GND
5
DSR
6
RTS
7
CTS
8
RI
9
5
Push the back panel and the CCD head block back
into their previous positions, and tighten the
Philips screws ( 7) to a torque of 0.18 N•m.
into their previous positions, and tighten the
Philips screws ( 7) to a torque of 0.18 N•m.
Connections
Communication
Specifications
Specifications
This unit utilizes an RS-232C-compliant, flow
controlled, synchronous serial interface.
Because the RS-232C setting is set to OFF when the
unit is shipped from the factory, you must change the
setting of the internal DIP switches to utilizes the RS-
232C function. (Before changing the settings make
absolutely sure that the power to the unit is turned off.
(See “Setting the RS-232C Switches” (page 11).))
controlled, synchronous serial interface.
Because the RS-232C setting is set to OFF when the
unit is shipped from the factory, you must change the
setting of the internal DIP switches to utilizes the RS-
232C function. (Before changing the settings make
absolutely sure that the power to the unit is turned off.
(See “Setting the RS-232C Switches” (page 11).))
The parameters are as follows.
Communication speed : 9600 bps
Data length
Communication speed : 9600 bps
Data length
: 8 bit
Stop bit
: 1 bit
Parity
: None
This is a no-flow-control, no-handshake protocol, each
bite is transmitted from the LSB line.
bite is transmitted from the LSB line.
Characters that can be transmitted are ASCII codes
30h to 39h, 41h to 5Ah (Alphabetic capital letters A to
Z, Arabic numerals 0 to 9), a space (20h), and a
Carriage Return (0Dh).
Thus the commands used to control the camera are
made up of the character set specified above, and each
command must end with a Carriage Return character
(0Dh).
30h to 39h, 41h to 5Ah (Alphabetic capital letters A to
Z, Arabic numerals 0 to 9), a space (20h), and a
Carriage Return (0Dh).
Thus the commands used to control the camera are
made up of the character set specified above, and each
command must end with a Carriage Return character
(0Dh).
Because this is a no-flow-control protocol, to prevent
communication overflows, if the host side sends one
byte, before sending the next byte, insert a 1 ms stop
period.
communication overflows, if the host side sends one
byte, before sending the next byte, insert a 1 ms stop
period.