Mounting and Adjusting the Lens
42
Cha
p
te
r 2  
P
rep
ar
at
ions
Caution
If the lens is not firmly locked, it may come off 
while the camcorder is being used. This could cause 
a serious accident. Make sure the lens is firmly 
locked. It is recommended that the lens mount 
securing rubber be put on the lens locking lever as 
illustrated above.
4
Connect the lens cable to the LENS 
connector.
5
Secure the lens cable with the cable 
clamps.
If you have attached an aberration correction 
lens
The aberration correction function is activated 
automatically. Starting the camcorder with an 
aberration correction lens may require more time 
than normally because of data loading at start-up.
The lens supplied with the PMW-350K is an 
aberration correction lens. Contact a Sony service 
representative for information about other 
aberration correction lenses.
If the lens does not stay in focus properly as you 
zoom from telephoto to wide angle, adjust the 
flange focal length (the distance from the plane of 
the lens mounting flange to the imaging plane). 
Make this adjustment just one time after 
mounting or changing the lens.
When carrying out the adjustment, use the 
supplied flange focal length adjustment chart as 
the subject.
Note
If you use a subject with insufficient contrast, or 
move the camcorder or subject during 
adjustment, this will cause an adjustment error.
Carrying out the adjustment
When using the auto focus lens
With the lens supplied with the PMW-350K, 
zoom and focus operations automatically adjust 
the flange focal length.
1
Open the iris, position the supplied 
flange focal length adjustment chart 
approximately 3 meters (10 ft) away 
from the camcorder, and arrange the 
lighting to obtain a satisfactory video 
output.
2
Set the ZOOM switch to SERVO 
(power zoom mode).
3
Hold down the flange focal length 
adjustment button for 3 seconds.
The flange focal length adjustment starts.
During adjustment
The message “AUTO FB EXECUTING” 
appears on the viewfinder screen.
If the adjustment completes correctly
The message on the viewfinder screen 
changes to “FB: OK”.
If the flange focal length adjustment does 
not complete correctly
Check the subject and lighting conditions, 
and repeat the adjustment.
When using a non-auto focus lens
1
Set the iris to manual.
2
Open the iris, position the supplied 
flange focal length adjustment chart 
approximately 3 meters (10 ft) away 
from the camcorder, and arrange the 
lighting to obtain a satisfactory video 
output.
3
Loosen the fixing screws on the F.f or 
F.B ring (flange focal length adjustment 
ring).
4
Use manual or power zoom to set the 
lens to telephoto.
5
Point the camcorder at the chart by 
turning the focus ring and focus on it.
Adjusting the Flange Focal Length
About 3 m (10 ft)