Справочник Пользователя для Lucent Technologies 555-670-111

Скачать
Страница из 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming Procedures 
3-143
Tie Trunks 
3
Console Display/Instructions
Additional Information
PC
6.
Select the type of channel unit.
7.
Save your entry.
Select 
Enter.
8.
Return to the System Programming menu.
Select 
Exit
 twice.
Tie Trunks
3
This section covers programming procedures for the following tie trunk options:
Direction
Tie Trunk Seizure Type
E&M Signal
Dial Mode
Tie Trunk Dial Tone
Tie Trunk Answer Supervision Time
Disconnect Time
Direction
3
Use this procedure to specify whether tie trunks operate in a one- or two-way 
direction. For one-way tie trunks, you must also specify whether the direction is 
out or in.
ChannelUnit DS1 Slot xx: 
xx
 = slot number entered in Step 3
Select one
Foreign Exchange
Special Access
Select 
Foreign
 
Exchange
 
 
Exit
Enter
or 
Special
 
Access.