Справочник Пользователя для Lucent Technologies 555-670-111

Скачать
Страница из 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Prior Releases: Features and Enhancements 
lviii
Release 1.1 Enhancements (October 1992) 
Maintenance
0
Maintenance enhancements include the following:
Clear descriptions of module test failures
Optional printing of hard copy of error logs
Display that correlates extension numbers with slot/port and logical ID
Display showing which slots, trunks, and extensions are maintenance busy
Internal digital switching element (DSE) loopback test for all modules
B-channel loopback test for MLX modules
B-channel line or call service states display
Error log entries for dual-port RAM errors
Release 1.1 Enhancements 
(October 1992)
0
Refer to 
Release 1.1 Notes
 
for detailed descriptions of Release 1.1 
enhancements. Release 1.1 includes all Release 1.0 functionality plus the 
enhancements described in the following sections.
Language Selection
0
This selection allows you to program the system for the display of prompts, 
menus, and messages on MLX display telephones in English, French, or Spanish. 
You can also program the following options in any of these languages, 
independently of the system language:
Individual extensions with MLX telephones
System Programming and Maintenance (SPM)
System programming reports
SMDR report headers
MLX-10D, MLX-20L, and MLX-28D display telephones and MLX-10 nondisplay 
telephones are available in three separate versions, with factory-set buttons in 
English, Spanish, or French. (The MLX-10DP is available in the English version 
only.) In addition, user and operator guides and telephone tray cards are available 
in all three languages.