Справочник Пользователя для Enerco MHVFR30LPT

Скачать
Страница из 20
7
Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
Figure 4
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket in located on the back panel of 
heater (see figure 5). It has been taped there for ship-
ping. Remove mounting bracket from back panel.
Figure 5
Removing Front Panel of Heater 
1.  Remove three screws on bottom front of front 
panel.
2.  Pull bottom of front panel forward, then down 
(see figure 6)
Figure 6
Attaching Mounting Bracket to Wall
Use holes on each end of mounting bracket to attach 
bracket to wall. These holes are 16 inches apart. Attach 
mounting bracket to wall in one of two following ways.
1.  Attach to wall studs
2.  Attach to wall anchor
Attaching to Wall Stud:
This way is the best providing the strongest mounting in 
wood frame houses. 
Attaching to Wall Anchor: 
This way allows you to attach mounting bracket to hol-
low walls (wall areas between studs) or to solid walls 
(concrete or masonry).
Decide which way best suits your needs. Either method 
will provide a secure hold for the mounting bracket.
1.  Tape mounting bracket to wall where heater 
will be located. Make sure mounting bracket is 
level. For wall stud mounting locate one end of 
the mounting bracket over a wall stud.
WARNING: Maintain minimum clearances shown in 
figure 7. If you can, provide greater clearances from 
the floor and joining wall. 
2.  Mark screw locations on wall (see figure 7).
3.  Remove tape and mount bracket from wall.
Figure 7
Attaching to Wall Stud:
For attaching mounting bracket to wall studs
1.  Drill holes at marked locations using 9/64” drill 
bit.
2.  Place mounting bracket onto wall. Line up 
holes on each end of bracket with hole drilled in 
wall.
3.  Insert mounting screws through bracket and 
into wall studs.
4.  Tighten screws until mounting bracket is firmly 
fastened to wall studs.
Attaching to Wall using Anchor:
For attaching mounting bracket to hollow walls (wall ar-
eas between studs) or solid walls (concrete or masonry)
Note: Wall anchors, mounting screws, and spacer 
are in hardware package. The hardware package is 
provided with heater. 
Adjoining W
all
17-1/2” Min.
6-1/2” Min. 10,000 BTU
10-1/4” min 20,000-30,000 BTU
16” (Lg)
12-9/64” (Sm)
Mark mounting hole locations 
and drill holes where indicated. 
Allow for minimum clearances
Left 
Side
Right 
Side
36” min. from 
ceiling
6” Min from 
adjoining 
walls
2” min. to top surface of carpet, tile 
or other combustible material
Floor
Mounting 