TROUBLESHOOTING GUIDE
PROBLEM            PROBABLE CAUSE                     SOLUTION
*NOTE: If blades will not turn by hand, contact your nearest service representative.
When switching from medium to low speed, you may notice some fan wobble. When fan speed stabilizes at low speed, wobble will 
disappear. If you have checked the above problems and still have trouble, call (901) 745-9222.
1.  Nothing happens;
fan does not move.*
2. Noisy operation.
3. Excessive wobbling.
1. Power turned off or fuse blown.
2.  Loose wire connections or 
wrong connections. 
3. Weak battery in transmitter.
4. Transmitter too far from fan.
5. Transmiter/Receiver switches in wrong position.
1. Blade irons loosely screwed to motor.
2. Blade screwed loosely to blade iron.
3. Blade cracked.
4. Light globe noisy.
1. Unbalanced blades.
2. Fan too close to vaulted ceiling.
3. Loose blades or blade brackets.
4. Fan not secure on hanger assembly.
1. Turn power on or replace fuse.
2.  Loosen canopy. Check all connections. 
(Turn power off while checking.)
3. Install new 9V battery.
4. Maximum range is 15-30 feet.
5. Set switches to matching positions.
1. Tighten screws until snug.
2. Tighten screws.
3. Replace blades.
4. Adjust globe.
1. Use blade balancing kit. (See Step 8D.)
2. Lower or move fan.
3. Tighten all screws.
4.  Turn power off. Support fan very carefully.
Loosen canopy and hang correctly.
Hunter fans have the power to cut your cooling costs up to 40%.
Beat the High Cost of Cooling
e air movement created by a Hunter ceiling fan lets you set your 
thermostat  higher  and  still  stay  comfortable.    Every  degree  you 
raise the thermostat saves up to 7% on energy costs.  So, you can 
cut  back  on  expensive  air  conditioning...and  save  up  to  40%*  on 
cooling.  In winter, your Hunter fan recirculates warm air and saves 
up to 10%* on heating bills.
*Your  savings  many  vary  based  on  climate,  building  type  and 
thermostat setting.  On average at low speed settings.
Save Energy and Money While Protecting the 
Environment
Congratulations!    You’re  saving  energy  and  money  while 
protecting  the  environment  by  purchasing  this  ENERGY  STAR 
qualified  Hunter  ceiling  fan!    With  this  purchase,  you  are  doing 
your  part  to  protect  the  environment.    In  2010,  ENERGY  STAR 
qualified  ceiling  fans  are  projected  to  cut  air  pollution  by  more 
than 500 million pounds!
Your  new  ceiling  fan  has  earned  the  ENERGY  STAR  label 
because  it  meets  high  energy  efficiency  specifications  set  by 
the  Environmental  Protection  Agency  (EPA).  ENERGY  STAR 
labeled ceiling fans save energy because they have more efficient 
fan  motors  and  air  delivery  due  to  more  aerodynamic  blade 
configurations.  Ceiling fan models bearing the ENERGY STAR label 
move air 14 - 20% more efficiently than typical ceiling fan models. 
For more information on ENERGY STAR visit www.energystar.gov.