Справочник Пользователя для Rinnai RCE-560PTR

Скачать
Страница из 71
Convector 460/560PTR
- 27 -
©Rinnai
11.  Error Code Messages
Error Code Messages
* If the safety devices activate while either (or both) the heater and air purifier are operating, both
will cease operating.
* When the unit is off, press the “override” and “
∨” buttons simultaneously for at least 2.5 seconds
to display the following at 2.5 second intervals in this order:
Error History (No. 1 (most recent) ~ No. 5);
Estimated Combustion Time (x100H);
Combustion Frequency (x100 times);
Estimated Air Purifier Operation Time (x100H); and
Actual Air Purifier Operation Time (x100H).
* When the unit is off, press the “override” and “
∧” and “∨” buttons simultaneously for 2.5 seconds
to reset Error History and Actual Air Purifier Operation Time.
Error 
Code
Content
Diagnostic Check Point
00
Power re-instatement while ON/OFF switch ON
-
03
Gas interrupted due to Tilt Switch activation
Check Tilt Switch
05
Detection of Loose Primary Filter
Check Primary Filter
11
Mis-ignition
Check Thermocouple Output
12
Incomplete Combustion Activation
Flame Failure
Check Thermocouple Output
14
Overheat Thermistor Activation
Check Overheat Thermistor
14
Reverse Flame Safety Device
Check Reverse Flame Sensor 
Switch
14
Thermal Fuse Melted
Check Thermal Fuse
16
High Temp. Cut off (10 minutes at > 40 C)
Check Room Temperature 
Thermistor
31
Room Temperature Thermistor broken circuit
Check Room Temperature 
Thermistor
32
Room Temperature Thermistor short circuit
Check Room Temperature 
Thermistor
33
Overheat Thermistor broken circuit
Check Overheat Thermistor
34
Overheat Thermistor short circuit
Check Overheat Thermistor
62
Faulty Fan Motor rpm
Check Convection Fan Motor
70
Heater ON/OFF switch abnormal
Check Control PCB
(ON/OFF Switch)
71
Solenoids or modulating valve circuit abnormal
-
72
Thermocouple initial value abnormal
Check Thermocouple output
72
Thermocouple high cut-out
(> 48mV for 5 secs)
Check Thermocouple output
73
Communication Error between PCB & E
2
PROM 
-
°