9 - 19
MELSEC-F
WHEN COMMUNICATING DATA USING THE MC PROTOCOL
9
9 - 19
9.3.2 Batch read in bit units (command: 00)
The examples shown in this section explain the command/response format when 
batch-reading the bit device memory.
For more details on the order and contents of data items of the areas marked by " " 
shown in the control procedure diagram, see Subsection 9.1.2.
[Control procedure]
Reading the on/off status of M100 to M111 of the PLC on which the FX
3U
-ENET-L is 
loaded.
(1) Communication in binary code
NOTE
Use the designation "00
H
" when the number of device points is 256 points.
0A
H
64
H
00
H
Subheader
PC No.
Number of device points
Head device
(Data name)
External device
side
(Example)
(Data name)
PLC side
(Example)
00
H
FF
H
00
H
00
H
00
H
20
H
4D
H
0C
H
00
H
80
H
Subheader
Complete code
00
H
10
H
10
H
10
H
10
H
10
H
10
H
Data for the number
of designed device
points
Characters for the
number of device
points
0
1
0
1
0
1
0
1
0
1
0
1
 Status
of M100
 Status
of M101
 Status
of M102
 Status
of M103
 Status
of M104
 Status
of M105
 Status
of M106
 Status
of M107
 Status
of M108
 Status
of M109
 Status
of M110
 Status
of M111
Monitoring
timer
H
L
L
-
-
-
-
H