Справочник Пользователя для Mitsubishi Electronics fx3u
9 - 36
MELSEC-F
WHEN COMMUNICATING DATA USING THE MC PROTOCOL
9
9 - 36
9.4.2 Remote RUN (command: 13) / Remote STOP(Command: 14)
The examples shown in this section explain the control procedure of remote RUN.
The order and content of data items of the areas marked by " " shown in the control
procedure diagram differ depending on the module used as well as the frame and
format used for communication.
See the detailed information described in Subsection 9.1.2.
The order and content of data items of the areas marked by " " shown in the control
procedure diagram differ depending on the module used as well as the frame and
format used for communication.
See the detailed information described in Subsection 9.1.2.
[Control procedure]
(1) Executing remote RUN while communicating in binary code
(2) Executing remote RUN while communicating in ASCII code
(Data name)
93
H
FF
H
0A
H
00
H
L
H
/94
H
13
H
/14
H
00
H
External device
side
side
(Example)
(Data name)
(Example)
PLC side
Subcommand
PC No.
Monitoring
timer
Complete code
Subcommand
For remote STOP 14
H
For remote RUN 13
H
For remote STOP 94
H
For remote RUN 93
H
*
*
F
31
H
1
33
H
3
46
H
46
H
30
H
0
30
H
0
30
H
0
41
H
A
F
H
L
H
L
39
H
9
33
H
3
30
H
0
30
H
0
H
L
(Data name)
External device
side
side
(Example)
(Data name)
(Example)
PLC side
Subcommand
PC No.
Monitoring
timer
Complete code
Subcommand
For remote RUN 3933
H
(93
H
)
For remote STOP 3934
H
(94
H
)
For remote RUN 3133
H
(13
H
)
For remote STOP 3134
H
(14
H
)