Страница из 284
11 - 6
MELSEC-F
TROUBLESHOOTING
11
11 - 6
11.2 How to Check an Error Through FX Configurator-EN-L
The status of the various settings for the Ethernet module can be checked using the 
FX Configurator-EN-L functions.
(1) Ethernet diagnostics (See Section 11.2.2.)
The block status of an Ethernet module, parameter settings, communication 
status, error log and others can be checked using the diagnostic function.
The following are the functions of the diagnostics.
(2) Buffer memory batch monitor (See Section 11.3.)
The buffer memory of an Ethernet module is monitored.
POINT
See Subsection 11.2.1 for the buffer memory that can be checked on the 
"Ethernet diagnostics" screen.
Diagnostics
Parameter status
Error log
Status of each connection
Status of each protocol
LED status
Send e-mail information
PING  test
COM.ERR. off
   Checks the stored parameters after the 
   initial processing for the Ethernet module. 
   (See Section 5.2.)
See Section 5.4
   Checks the error stored in the error log area. 
   (See Section 11.4.)
   Checks the status of each connection after the 
   connection to the external device is established 
   with the open processing. (See Section 5.6.)
   Checks the communication status of each 
   protocol supported by the Ethernet module.
   Checks the on/off status of the LED on the 
   front of the Ethernet module. (See Section 11.1.)
   Checks the information for sent e-mail. 
   (See Section 11.4.)
   Turns off the [COM.ERR.] LED on the front 
   of the Ethernet module. 
See Subsection 11.1.2
   Checks the completion of the initial processing 
   with the issuance of the PING command.