Manning AirAlert-96d Gas Monitor
 
19073 AIRALERT96D 05/2006 Prelim REVC  Copyright © 2006 Honeywell Analytics. All Rights Reserved.
 
3
 
1
 Introduction 
Warning 
To ensure your personal safety, read “Safety 
Information” (below) before you use the controller. 
The AirAlert
TM
96d system sets new standards in gas 
detection and in the measurement of environmental 
parameters. 
Acting as the nerve center of a modular gas detection 
network, the AirAlert
TM
96d provides continuous 
monitoring of up to 96 connected units on three 
distinct channels.  
The AirAlert
TM
96d provides a full array of displays. At 
a glance, it is possible to determine the status of the 
entire network. Field modifications are straight-
forward. A menu driven program allows for minor 
fine-tuning of the sequence of operation all the way 
to the reconfiguration of the entire network. 
Since no two projects are alike, the AirAlert
TM
96d is 
designed to be highly customized. Combined with 
ease of installation, this unit represents the most 
affordable gas monitoring solution for institutional, 
commercial and light industrial applications. 
For more advanced applications, the AirAlert
TM
96d 
controller provides datalogging capacity within a 
cast aluminum enclosure. The perfect solution for 
even the most complex of industrial applications. 
A
 
Safety Information — Read First 
Use the controller only as specified in this manual, 
otherwise the protection provided by the controller 
may be impaired. 
Read the 
Warnings and Cautions on the following 
pages before using the controller. 
Note:  This instrument contains a lithium battery. 
Do not mix with the solid waste stream. Spent 
batteries should be disposed of by a qualified 
recycler or hazardous materials handler.
 
• 
Warning:  To prevent ignition of flammable 
or combustible atmospheres, disconnect 
power before servicing.
 
• 
Do not use the controller if it is damaged. 
Before you use the controller, inspect the 
case.
  
• 
If the controller is damaged or something is 
missing, contact Honeywell Analytics 
immediately.
 
To avoid possible damage to the controller: 
• 
Do not expose the controller to electrical 
shock and/or severe continuous mechanical 
shock.
 
• 
Do not attempt to disassemble, adjust, or 
service the controller unless instructions for 
that procedure are contained in the manual 
and/or that part is listed as a replacement 
part. Use only Manning replacement parts.
 
The controller Warranty could be voided if customer 
personnel or third parties damage the controller 
during repair attempts.  
B
 
Getting Started 
Intended Use 
The AirAlert
TM
96d controller will provide around the 
clock monitoring of the gas detection network. 
Moreover, a log of all the sensors concentrations and 
alarms will be created for analysis with the data-
logger option. Also, the grouping/zoning capabilities 
will result in energy cost savings. 
Figure 1. AirAlert
TM
96d 
Caution 
To avoid possible personal injury: 
• 
Warning:  Substitution of components may 
impair intrinsic safety.
 
 
 
 
Manning AirAlert  96d
Warn
Alarm
High Alarm
Fault
Power
Enter
ESC
Silence
TX
RX