Справочник Пользователя для Monessen Hearth HDV500NV/PV

Скачать
Страница из 64
56D3048
11
HDV Series Direct Vent Gas Fireplace
oPtIoNAl toP VeNt INStAllAtIoN
oPtIoNAl toP VeNt APPlICAtIoN 
The appliance is shipped as a rear vent unit. If the installa-
tion layout requires the unit to be a top vent configuration 
the  appliance  can  be  converted  by  following  the  steps 
below.
When  removing  and  refitting  the  plates  and  adapter  be 
sure the associated gaskets are undamaged and refitted 
as required.
1.  Remove  the  eight  (8)  screws  securing  the  flue  pipe 
adapter to the fireplace body. Figure 7
.  Set  the  flue  pipe  adapter  aside,  complete  with  the 
gasket. Do not damage the gaskets as the adapter and 
gasket must be refitted.
3.  Remove the eight (8) screws securing the flue pipe cover 
to the top of the intake box and remove the cover and 
gasket. Figure 7
W
ARNING
After conversion to top vent configuration 
the  5"  (127  mm)  flue  pipe  should  be 
concentric with the 8" (203 mm) outer collar 
within 1/4".
FP1991
remove screws
Flue Pipe 
Cover 
Flue Pipe 
Adapter 
Screws
FP1991
Figure 7 - 
Remove 16 Screws from Flue Pipe 
Adapter and Flue Pipe Cover 
4.  Remove  six  (6)  screws  securing  the  flue  pipe  to  the 
back of the intake box and remove the pipe and gasket. 
Figure 8
5.  Replace flue pipe to top of firebox. Ensure the gasket is 
in place and undamaged.  Secure with six (6) screws. 
Figure 9
6.  Place the flue pipe cover and gasket removed in step 
3 over the flue opening in bottom of the intake box.
7.  Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with six (6) screws removed 
in step 1.
Figure 8 - 
Remove Flue Pipe
FP1992
remove flue pipe
Screws 
Flue Cover 
Flue Pipe 
FP199
FP1993
attach flue pipe
Figure 9 -
 Attach Flue Pipe to Top 
Vent Configurations  
Flue Pipe 
Screws
FP1993