 P33-4 Zero Clearance Direct Vent Gas Fireplace
23
Flex Liner
Exhaust
Flue
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Air Intake
Co-linear DV
Vertical Termination
Cap # 946-529
Co-Linear
Flex
Adapter
with Kit#
946-563
Outer
Pipe
with Kit#
946-563
Inner Pipe
Adapter
with Kit#
946-563
Rigid Pipe Adapter
# 510-994
Pipe Length
45 Elbow
o
VERTICAL TERMINATION 
 WITH CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to 
two 3" (76mm) co-linear aluminium fl ex running 
the full length of the chimney. See the "Venting 
Arrangements - Vertical Terminations" Section 
for minimum and maximum heights.
Required Parts:
Part # 
Description
946-529 
Co-linear DV Vertical 
 Termination 
Cap
948-305 
3" Flex - 35 ft.
946-563 Co-Axial 
to 
Co-Linear Adapter Kit
 
which contains the following: 
 
Co-linear Flex Adapter  
 
 Outer 
Pipe
 Inner 
Pipe 
Adapter 
510-994 Rigid 
Pipe 
Adaptor
945 45
o
 Elbow 
Alternate Approved Caps
980 Vertical 
Termination 
Cap
991 High 
Wind 
Cap
923GK 3" Co-linear Adapter with fl ashing
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, 
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION
THE APPLIANCE MUST NOT BE 
CONNECTED TO A CHIMNEY FLUE 
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
FPI Cabinet and/or Flat Wall Mantles may 
be used in these applications ensuring 
that clearances to combustibles are 
maintained.