Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENTING
:
This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” 
PIPE  FOR  GAS  STOVES,  SECURITY  CHIMNEY’S  SECURE  VENT  DIRECT  VENT  SYSTEM  kits,  and  MDV 
SELKIRK METALBESTOS.
A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a 
horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11⁄2” (38 mm) on the 
sides and bottom. When combustible materials are directly above a 90° elbow, 5” (127 mm) of clearance 
are necessary (see Figure 20).
Table 5. Vent Pipe Minimum Clearances.
Vertical Pipe to 
the Side Walls
Horizontal Pipe to 
the Sides & Bottom
Above an Elbow 
Above the Unit
Above an Elbow 
Not Above the Unit
Above Horizontal 
Vent Pipe
Wall Frame  8” 
(203mm) or less
Hard 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
4”
(102 mm)
3”
(76.2 mm)
2”
(51 mm)
10”x10”
(25x25cm)
Flex 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
8”
(203 mm)
4 3/8”
(111 mm)
4 3/8”
(111 mm)
10”x10”
(25x25cm)
A 10” (254 mm) x 10” (254 mm) frame (see Figure 24) will assure the proper support and spacing for 
the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used 
for passing through walls and ceilings. All sealing and vapour barriers must comply with local building 
codes.
When planning an installation, it is necessary to select the proper length of vent pipe for the particular 
requirements.   The configuration of the venting pipes depends on the locations of walls, ceilings and 
2" (51mm)
4" (102mm)
10"
(254mm)
381⁄2"
(978mm)
Figure 24. Vent Framing Through Wall/Ceiling
Figure 23. Hard Vent Pipe Clearances.
studs.  However,  the  pipes  cannot  be  of  arbitrary  length 
and  arrangement.  Because  the  length  of  the  vertical  and 
horizontal sections dramatically affects the burning efficiency 
of  the  fireplace,  certain  guidelines  have  been  set  in  I
NITIAL
 
I
NSTALLATION
 - V
ENT
 C
ONFIGURATIONS
 
AND
 R
ESTRICTOR
 S
ETTINGS
.     
Venting terminals can not be recessed into a wall or siding.
WARNING: This gas appliance must not be connected 
to  a  chimney  flue  serving  a  separate  solid-burning 
appliances.