Figure 8 - Lineal Gain
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
42"
Fireplace
37 
1
/
2
"
12-8DM
12-8HT
Pipe Section
10 
5
/
8
"
18-8DM
18-8HT
Pipe Section
16 
5
/
8
"
24-8DM
24-8HT
Pipe Section
23 
5
/
8
"
36-8DM
36-8HT
Pipe Section
34 
5
/
8
"
48-8DM
48-8HT
Pipe Section
46 
5
/
8
"
RT-8DM
Round Termination
7
/
8
"*
RTL-8DM
Round Termination
3
/
4
"*
RTT-8DM
Round Termination 
with Slip Section
7
/
8
" to 
23 
1
/
8
"*
RTTL-8DM
Round Termination 
with Slip Section
1
/
2
" to  
21 
1
/
2
"*
ET-8DM
Square Chase-Top
12"*
ETO-8DM
Square Chase-Top 
with Mesh
12"*
ETL-8DM
Square Chase-Top 
with Slip Section
7" to 15"*
ETLO-8DM
Square Chase-Top 
with Mesh & Slip 
Section
12" to  
25 
1
/
2
"*
* The lineal gain for the terminations is 
measured to the flue gas outlet height.
Hemmed 
End
8" Stainless 
Inner Pipe
12 
3
/
8
Galvanized 
Outer Pipe
Figure 7 - Outside Air Kit
Secure to Collars with Metal Tape, Screws 
or Straps (Min. of 1/4" x 20" in size)
Air Inlet 
Location 
Must Allow 
For Bushes 
or Snow
Vent Hood 
Required for 
Wall Installation
Air Inlet 
Eyebrow
Vented Crawl Space 
(Check Local Codes 
Before Installing in a 
Vented Crawl Space)
VenTing inSTallaTion
OPTIONAL OUTSIDE AIR KIT 
(MODEL AK4/AK4F)
Installation  of  outside  air  kit  should  be  per-
formed during rough framing of fireplace due 
to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl 
space  (AK4F)  or  through  a  sidewall  (AK4). 
See Figure 24 on page 15 for instruction of 
operating air kit.
  CAUTION:  Combustion  air 
inlet  ducts  shall  not  terminate 
in attic space.
The  maximum  height  for  the 
air  vent  can  not  exceed  3  feet 
below the flue gas outlet of the 
termination.
CHIMNEY PIPE
FMI  PRODUCTS,  LLC  chimney  system 
consists of 12", 18", 24", 36" and 48" snap-
lock,  double-wall  pipe  segments,  planned 
for  maximum  adaptability  to  individual  site 
requirements. Actual lengths gained after fit-
ting overlaps must be taken into consideration 
(lineal gain) and are given in lineal gain chart 
(see Figure 8).
Lineal gain is actual measurable length of a 
part after two or more parts are connected.
  WARNING:  The  opening  in 
collar around chimney at top of 
fireplace must not be obstructed. 
Never use blown insulation to fill 
chimney enclosure.