Справочник Пользователя для Mitsubishi Electronics PCA-A.KA4

Скачать
Страница из 36
2
Contents
1. Safety 
precautions 
..................................................................................... 2
2. Installation 
location 
.................................................................................... 3
3.  Installing the indoor unit ............................................................................ 3
4.  Installing the refrigerant piping .................................................................. 5
5.  Drainage piping work ................................................................................. 6
6. Electrical 
work 
........................................................................................... 6
7. Test 
run 
.................................................................................................... 10
8.  Easy maintenance function (For wired remote controller only) ............... 12
1. Safety precautions
► 
Before installing the unit, make sure you read all the “Safety precau-
tions”.
► 
Please report to your supply authority or obtain their consent before 
connecting this equipment to the power supply system. 
 Warning:
Describes precautions that must be observed to prevent danger of injury or 
death to the user.
 Caution:
Describes precautions that must be observed to prevent damage to the unit.
After installation work has been completed, explain the “Safety Precautions,” use, 
and maintenance of the unit to the customer according to the information in the 
Operation Manual and perform the test run to ensure normal operation. Both the 
Installation Manual and Operation Manual must be given to the user for keeping. 
These manuals must be passed on to subsequent users.
 : Indicates a part which must be grounded.
 Warning:
Carefully read the labels affixed to the main unit.
 Warning:
•  Ask a dealer or an authorized technician to install the unit.
• For installation work, follow the instructions in the Installation Manual and 
use tools and pipe components specifically made for use with refrigerant 
specified in the outdoor unit installation manual.
• The unit must be installed according to the instructions in order to mini-
mize the risk of damage from earthquakes, typhoons, or strong winds. An 
incorrectly installed unit may fall down and cause damage or injuries.
•  The unit must be securely installed on a structure that can sustain its weight. 
•  If the air conditioner is installed in a small room, measures must be taken 
to prevent the refrigerant concentration in the room from exceeding the 
safety limit in the event of refrigerant leakage. Should the refrigerant leak 
and cause the concentration limit to be exceeded, hazards due to lack of 
oxygen in the room may result.
•  Ventilate the room if refrigerant leaks during operation. If refrigerant comes 
into contact with a flame, poisonous gases will be released.
•  All electric work must be performed by a qualified technician according to 
local regulations and the instructions given in this manual. 
•  Use only specified cables for wiring.
•  The terminal block cover panel of the unit must be firmly attached.
•  Use only accessories authorized by Mitsubishi Electric and ask a dealer or 
an authorized technician to install them.
• The user should never attempt to repair the unit or transfer it to another 
location.
•  After installation has been completed, check for refrigerant leaks. If refrig-
erant leaks into the room and comes into contact with the flame of a heater 
or portable cooking range, poisonous gases will be released.
1.1.  Before installation (Environment)
 Caution:
• Do not use the unit in an unusual environment. If the air conditioner is in-
stalled in areas exposed to steam, volatile oil (including machine oil), or sulfu-
ric gas, areas exposed to high salt content such as the seaside, the perform-
ance can be significantly reduced and the internal parts can be damaged.
•  Do not install the unit where combustible gases may leak, be produced, 
flow, or accumulate. If combustible gas accumulates around the unit, fire or 
explosion may result.
•  Do not keep food, plants, caged pets, artwork, or precision instruments in 
the direct airflow of the indoor unit or too close to the unit, as these items 
can be damaged by temperature changes or dripping water.
• When the room humidity exceeds 80% or when the drainpipe is clogged, 
water may drip from the indoor unit. Do not install the indoor unit where 
such dripping can cause damage.
•  When installing the unit in a hospital or communications office, be pre-
pared for noise and electronic interference. Inverters, home appliances, 
high-frequency medical equipment, and radio communications equipment 
can cause the air conditioner to malfunction or breakdown. The air con-
ditioner may also affect medical equipment, disturbing medical care, and 
communications equipment, harming the screen display quality.
1.2.  Before installation or relocation
 Caution:
•  Be extremely careful when transporting the units. Two or more persons are 
needed to handle the unit, as it weighs 20 kg, 44 lbs or more. Do not grasp 
the packaging bands. Wear protective gloves as you can injure your hands 
on the fins or other parts.
•  Be sure to safely dispose of the packaging materials. Packaging materials, 
such as nails and other metal or wooden parts may cause stabs or other 
injuries.
•  Thermal insulation of the refrigerant pipe is necessary to prevent condensa-
tion. If the refrigerant pipe is not properly insulated, condensation will be 
formed.
•  Place thermal insulation on the pipes to prevent condensation. If the drain-
pipe is installed incorrectly, water leakage and damage to the ceiling, floor, 
furniture, or other possessions may result.
•  Do not clean the air conditioner unit with water. Electric shock may result.
•  Tighten all flare nuts to specification using a torque wrench. If tightened 
too much, the flare nut can break after an extended period.
1.3.  Before electric work
 Caution:
•  Be sure to install circuit breakers. If not installed, electric shock may result.
•  For the power lines, use standard cables of sufficient capacity. Otherwise, 
a short circuit, overheating, or fire may result.
•  When installing the power lines, do not apply tension to the cables.
•  Be sure to ground the unit. If the unit is not properly grounded, electric 
shock may result.
• Use circuit breakers (ground fault interrupter, isolating switch (+B fuse), 
and molded case circuit breaker) with the specified capacity. If the circuit 
breaker capacity is larger than the specified capacity, breakdown or fire 
may result.
1.4.  Before starting the test run
 Caution:
•  Turn on the main power switch more than 12 hours before starting opera-
tion. Starting operation just after turning on the power switch can severely 
damage the internal parts.
•  Before starting operation, check that all panels, guards and other protec-
tive parts are correctly installed. Rotating, hot, or high voltage parts can 
cause injuries.
•  Do not operate the air conditioner without the air filter set in place. If the air 
filter is not installed, dust may accumulate and breakdown may result.
•  Do not touch any switch with wet hands. Electric shock may result.
•  Do not touch the refrigerant pipes with bare hands during operation.
•  After stopping operation, be sure to wait at least five minutes before turn-
ing off the main power switch. Otherwise, water leakage or breakdown may 
result.