60
9-3-4. Only outdoor fan does not run.
9-3-5. Only compressor does not run.
• Check compressor motor                
capacitor.
• Measure resistance of PTC 
thermistor.
• Measure resistance of 
compressor motor winding.
• Measure resistance of power 
relay.                              (PR)
NO
YES
YES
 Overload relay is working.
YES
Temperature of compressor 
is abnormally high.
Refrigerant gas shortage.
Charge refrigerant gas (R22).
Rotor may be locked up.
• Measure Power supply
voltage.
The voltage is too low.
No
Fan cannot
be turned.
OK
• Check fan rotation. 
Turn fan gently once or twice by 
hand.
• Check fan casing 
foreign matter on 
inside.
Fan motor burnout 
or foreign matter in 
bearings.
Remove foreign 
matter or repair.
Repair or replace.
• Measure resistance of indoor fan 
motor winding.
• Check fan motor capacitor.
000-111 
SM 
(18-68) 
 
00.3.17 
11:49 
AM 
  y [ W  60