Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. 
Proper installation is your responsibility. Make sure you have 
everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the 
power cord exits the air conditioner. 
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner and sleeve 
(sold separately). 
Adequate wall support for weight of air conditioner. 
Electrical Requirements
The electrical ratings for your air conditioner are listed on the 
model and serial number label. The model and serial number 
label is located behind the front panel on the front flange above 
the coil area. 
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Recommended ground method
This air conditioner must be grounded. This air conditioner is 
equipped with a power supply cord having a grounded 3 prong 
plug. To minimize possible shock hazard, the cord must be 
plugged into a mating, grounded 3 prong outlet, grounded in 
accordance with all local codes and ordinances. If a mating outlet 
is not available, it is the customer's responsibility to have a 
properly grounded 3 prong outlet installed by a qualified electrical 
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 - 
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
Power Supply Cord
NOTE: Your unit’s device may differ from the one shown.
This room air conditioner is equipped with a power supply cord 
required by UL. This power supply cord contains state-of-the-art 
electronics that sense leakage current. If the cord is crushed, the 
electronics detect leakage current and power will be 
disconnected in a fraction of a second. 
Power supply cord 
Wiring requirements
115-volt (103.5 min. - 
126.5 max.)
0-7.5 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.
115-volt (103.5 min. - 
126.5 max.)
7.6-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230/208 volt (197.6 min. - 
253 max.)
0-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
A. Reset button
B. Test button
Power supply cord 
Wiring requirements
¹⁄₄
"
(0.6 cm)
TEST
RESET
A
B