Справочник Пользователя для Heatiator BCDV36

Скачать
Страница из 28
01-03
13
33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
1. ATTACHING THE VENTING TO THE
APPLIANCE
To attach the first VP section to the appliance collars,
simply slide the flared end of the inner vent of the VP
section over the inner collar on the appliance. At the
same time, insert the outer  vent into the outer collar
on  the  appliance.  Push  the  vent  section  into  the
appliance collar until all the lances have snapped in
place.  Tug  slightly  on  the  vent  to  confirm  it  has
completely locked into place.
2. ASSEMBLING  VENT  SECTIONS
a. Start  the  flared  inner  flue  of  section  “A”  over  the
inner flue of section “B”.
b. Insert  the  outer  flue  of  section  “A”  into  the  outer
flue of section “B”. See Figure 19. Once both inner
and outer flues are started, press section “A” into
section  “B”  firmly  until  all  lances  have  snapped
into place. Tug slightly on section “A” to confirm it
has completely locked into place. See Figure 20.
Note: 
Squeezing the pipe slightly to fit may be
necessary.
Note: 
Make  sure  that  the  seams  are  not  per-
fectly  aligned  to  prevent  unintentional  discon-
nection.
Figure 19
Figure 20
Figure 21
3. ASSEMBLING  MINIMUM  INSTALLATIONS
(MI)  SECTIONS
MI sections are non-unitized so that they can be cut to
a certain length. To use these sections, they must be
cut to length from the non-expanded end. See Figure
21. They can then be attached by first connecting the
expanded end of the MI inner vent with the inner vent
from the adjacent vent section and securing with three
screws. The expanded portion of the MI inner vent must
overlap  completely  with  the  untreated  end  of  the
adjacent  vent  section.  The  outer  vent  can  then  be
inserted  into  the  adjacent  outer  vent  expanded  end
and attached to the next vent section with three screws.
The  other  end  of  the  MI  vent  section  can  then  be
attached by fitting a snap lock section to it and snapping
it together as normal.
G. ASSEMBLING VENT SECTIONS