Справочник Пользователя для A.O. Smith ADMP - 90

Скачать
Страница из 6
www.aosmithinternational.com
Data subject to change INT/0808/ADMR/01
Terms and conditions apply
, please refer to our website.
ADMP / ADM / ADMR
Electrical diagram ADMR
TERMINAL STRIP CONNECTIONS
 
Earth 
N  
Neutral
L1 
Phase input of controller
L2  
Phase input of program-
 
controlled pump
L3  
Phase input of continuous pump
L4  
Phase input of extra error signal
L5  
Phase input of flue damper 
 
motor
L6  
Phase output of flue damper 
 
motor (feedback)
L7  
Phase input of isolating  
 
 
transformer (primary side)
L8  
Phase output of isolating  
 
 
transformer (secondary side)
COMPONENTS
A  
Controller
B  
Gas control
C  
Glow igniter
D  
Ionisation rod
E  
Extra error signal
F  
Double-pole mains switch
G  
Program-controlled pump
H  
Continuous pump
J  
Flue damper
K  
Isolating transformer
L  
I/0 switch control
M  
Display/Flat cable
N  
Extra ON mode switch
O  
Connector for the flue gas sensor
P  
Temperature sensor 
 
(T2 - bottom of tank)
Q  
Temperature sensor 
 
(T1 - top of tank)
R  
Selection resistor
CONTROLLER CONNECTIONS
J1  
Connector for display to controller
J2  
Connector for power supply to   
 
controller
J19   Connector for extra error signal  
 
and power supply to flue damper
J20   Connector for gas control
J21   Connector for program-
 
controlled pump
J29   Connector for feedback from flue  
 
damper
JP2   Connector for ionisation rod and  
 
glow igniter
JP3   Connector for temperature 
 
sensor T2
JP4   Connector for flue gas sensor
JP5   Connector for temperature 
 
sensor T1
JP6   Connector for selection resistor 
 
and feedback from micro-switch
JP8   Connector for extra ON mode 
 
switch
F1  
Fuse
F2  
Fuse