CT3451 PROGRAMMABLE THERMOSTAT
3
69-1620—1
3 MOUNT WALLPLATE
IMPORTANT
Level for appearance only. The thermostat func-
tions normally even when not mounted level.
Position the wallplate on the wall. Level the wallplate 
for appearance, if desired. Use a pencil to mark the 
two mounting holes that best fit the application. See 
Fig. 3.
Fig. 3. Mounting wallplate to wall.
Remove the wallplate from the wall and drill two 3/16-
in. holes in the wall (if drywall). For firmer wall material 
such as plaster or wood, drill 7/32-in. holes. Gently tap 
provided anchors into the drilled holes until flush with 
the wall.
Reposition the wallplate, pulling wires through the 
wiring opening. Loosely insert the mounting screws 
into the holes.
Level for appearance only; the thermostat functions 
correctly even when not level. Tighten the mounting 
screws.
4 WIRE WALLPLATE TERMINALS
All wiring must comply with local electrical codes and 
ordinances. If unsure about household wiring 
procedures, call your local heating and air conditioning 
contractor.
Refer to the labels you placed on wires when you 
removed your old thermostat.
Match the letter of your old thermostat wire with the 
terminal of the corresponding letter on your new 
thermostat. Refer to Fig. 4.
Fig. 4. Connecting wiring.
NOTE: To ensure correct mounting of thermostat, 
restrict all wiring to the shaded area in the cen-
ter of the terminals.
Loosen the terminal screws and slip each wire 
beneath its matching terminal. The shape of the 
terminals permit insertion of straight or wraparound 
connections. See Fig. 5. Tighten the terminals.
Fig. 5. CT3451 methods for wiring connection.
Plug the hole in the wall with insulation to help prevent 
drafts from adversely affecting thermostat operation.
The CT3451 Thermostat is powered with 3AA alkaline 
batteries and is adaptable to most 18 to 30 Vac heating-
cooling systems. Refer to Fig. 6 through 10 for typical 
system wiring diagrams.
M12202A
WALL
WALL  
ANCHORS (2)
WALLPLATE
WHEN USING WALL ANCHORS, DRILL 3/16 INCH 
HOLES FOR DRYWALL, 7/32 INCH HOLES FOR
PLASTER OR WOOD.
MOUNTING 
SCREWS (2)
1
1
TERMINAL 
SCREW
M12559A
G
R
Rc
Y
W
B
O
FOR STRAIGHT 
INSERTION STRIP 
5/16 IN. (8 MM)
FOR WRAPAROUND 
STRIP 7/16 IN. (11 MM)
M12537
FOR WRAPAROUND, STRIP 
7/16 IN. (11 mm)
FOR STRAIGHT INSERTION,
STRIP 5/16 IN. (8 mm)