INSTALLATION OF HORIZONTAL THROUGH THE 
WALL VENT SYSTEM
If you are installing your system so that it vents through roof, please 
refer to section titled VERTICAL VENT TERMINAL INSTALLATION.
VENT TERMINAL INSTALLATION, SIDEWALL
1.  Install the vent terminal by using the cover plate as a template to 
mark the hole for the vent pipe to pass through the wall. BEWARE 
OF CONCEALED WIRING AND PIPING INSIDE THE WALL.
2.  If the Vent Terminal is being installed on the outside of a finished 
wall, it may be easier to mark both the inside and outside wall. 
Align  the  holes  by  drilling  a  hole  through  the  center  of  the 
template from the inside through to the outside. The template 
can now be positioned on the outside wall using the drilled hole 
as a centering point for the template.
3.  A) MASONRY SIDE WALLS
  Chisel an opening approximately one half inch (1.3 cm) larger 
than the marked circle.
  B) WOODEN SIDE WALLS
  Drill a pilot hole approximately one quarter inch (0.64 cm) outside 
of the marked circle. This pilot hole is used as a starting point 
for a saws-all or sabre saw blade. Cut around the marked circle 
staying approximately one quarter inch (0.64 cm) outside of the 
line. (This will allow the vent to easily slide through the opening. 
The resulting gap will be covered up by the Vent Terminal cover 
plate.) Repeat this step on inside wall if necessary.
Cut a length of pipe about 3.5 inches (8.9 cm) longer than the wall 
thickness at the opening. Glue the vent terminal to this section of pipe. 
Slide the wall plate over the pipe to stop against the vent terminal. 
Place a bead of caulking (not supplied) around the gap between the 
pipe and cover plate. Apply enough to fill some of the gap between 
the pipe and wall. Place some of the caulking on the back of the plate 
to hold it against the wall after installation. If the vent pipe is installed 
up to the wall, with a coupling on the end against the wall opening, 
the pipe with the vent terminal can be prepared for gluing before 
inserting through the wall. Slide the pipe through the wall and insert 
into the coupling on the other side of the wall, making sure that the 
vent terminal ends up pointed in the correct position, see Figure 12.
Figure 12: VENT TERMINATION
VENT PIPE TERMINATION
The first step is to determine where the vent pipe will terminate. See 
Figures 12, “Figure: 13A”, and “Figure: 14”. The vent may terminate 
through a sidewall as shown in Figure 12 and  “Figure: 14” or through 
the roof as shown in “Figure: 15” and “Figure: 16”.
The  vent  system  must  terminate  so  that  proper  clearances  are 
maintained  as  cited  in  local  codes  or  the  current  edition  of  the 
National Fuel Gas Code, (ANSI Z223.1, 12.9.1 through 12.9.4) or 
the Natural Gas and Propane Installation Code (CAN/CSA-B149.1). 
See “Figure: 15” and “Figure: 16”.
Instructions on proper installation through a sidewall are provided 
in Figures 12, “Figure: 13A”, and “Figure: 14”.
Plan  the  vent  system  layout  so  that  proper  clearances  are 
maintained from plumbing and wiring.
Vent pipes serving power vented water heaters are classified by 
building  codes  as  vent  connectors.  Required  clearances  from 
combustible  materials  must  be  provided  in  accordance  with 
information in this manual under FACTS TO CONSIDER ABOUT 
LOCATION and INSTALLING THE WATER HEATER, and with the 
National Fuel Gas Code and local codes.
PLANNING THE VENT SYSTEM
Plan the route of the vent system from the exhaust elbow to the 
planned location of the vent terminal.
1. Layout  total  vent  system  to  use  a  minimum  of  vent  pipe  and 
elbows.
2. This water heater is capable of venting flue gases in equivalent 
feet of pipe as listed in Table 7.
Table 7
Number of 
90° Elbows
2” Maximum 
Pipe - ft. (m)
3” Maximum 
Pipe - ft. (m)
1
40 (12.19)
120 (36.57)
2
35 (10.66)
115 (35.05)
3
30 (9.14)
110 (33.52)
4
25 (7.62)
105 (32)
5
20 (6.09)
100 (30.48)
6
15 (4.57)
95 (28.95)
The minimum vent length for each of the pipe size is one 90° elbow 
plus 2’ and 7’ (0.61 m and 2.1 m) of straight pipe for air intake and 
exhaust vent respectively and the appropriate termination.
  NOTE: The equivalent feet (m) of pipe listed above are exclusive 
of  the  termination.  That  is,  the  termination,  with  an  installed 
screen, is assumed to be in the system and the remainder of 
the system must not exceed the lengths and number of elbows 
shown in Table 7.
  If using 2” inch vent pipe: A 2” diameter vent pipe must be 
inserted and glued to the exhaust elbow assembly.
  If using 3” inch vent pipe: Two inches (5.1cm) of 2” diameter pipe 
must be inserted and glued to the exhaust elbow assembly before 
adding a 2’ x 3” reducer to acquire the desired pipe diameter. A 
3” coupling (supplied locally-a schedule 40 DWV) vent terminal 
must be obtained. A 3” diameter screen is supplied in the vent 
kit.